Ducting connections With two hoses (2 x 100 mm dia.) on the exhaust, dry, hot air can be passed under a
surface such as a floor.
Dantherm recommends connection of max. 5 metres of flexible ducting per connection
spigot.
Heating element
CDT 30S/40S has one 1 kW integrated heating element. When the element is active, the
dehumidification process is accelerated. See page 11 of the user guide for heating ele-
ment operation.
Water container
Condensate water is collected in the water container or it can be piped to a drain via a
hose spigot (optional accessory).
The dehumidifier cuts out automatically when the container is full. See the user guide
for emptying the water container. The dehumidifier cannot operate when the container
is removed.