User guide,
cont.
Error messages
An overview of possible errors which prevent normal operation
Error message
Illustration
Cause
Remedy
Yellow light on
centre LED with
emptying symbol
and FULL on display
Water container full See guide below for emptying
Red light on right
warning LED HIGH
TEMP on display
Pressure or tem-
perature in high
pressure element
too high
Check filter and dehumidifier
for dirt in airways
Red light on right
warning LED AMBI-
ENT TEMP on
display
Room temperature
out of normal range
Place the dehumidifier in the
specified temperature range,
between 3°-32°C
Red light on right
warning LED SEN-
SOR FAIL on
display. One of the
internal sensors is
defective. Use the
+/- keys to toggle
between 3 possible
errors
SENSOR FAIL
1: EVAP FAIL
Evaporator
thermometer
defective
Requires an authorised ser-
vice technician
2: COND FAIL
Condenser
thermometer
defective
Requires an authorised ser-
vice technician
3: ROOM FAIL The
internal room
thermometer is
defective
Requires an authorised ser-
vice technician
Red light on right
warning LED LP
STOP on display
Leak in cooling
circuit
Requires an authorised ser-
vice technician
Continued on next page