27
05332
6
•
Ve
rs
io
n
1
.0
•
13
-12
-2019
en
Appendix
Technical data
General data
The table below shows the general technical data:
Data
unit
CDT 30S
CDT 40S
Range - humidity
%RH
40-100
%RH hysteresis
%RH
4
Range - temperature
°C
3-35
Mains connection
V/Hz
1N
230+PE/50
Duct connections
mm
Ø100
Max. ampere rating
A
7.9
8.4
Max. effect consumed with heating
element
kW
1.8
1.9
Air production
m
3
/h
350/300*
560/460*
Refrigerant
-
R454C
Refrigerant filling
kg
0.41
0.45
GWP (Global Warming Potential)
-
146
Water container capacity
l
7.0
14.0
Noise level at 1 m distance
dB
60**
62**
Weight
kg
34
42
Protection class
IP
x4
Filter
PPI
15
kWh accuracy
%
±5 %
*) Free-blowing/through 5m hose **) with airducts mounted