P
AGE
14
46034-0997 <90-00030>
INSTALLATION
T
ABLE
D (
CONTINUED
)- S
WITCH
S
ETTINGS
3. Wire the connector.
The 56-pin connector is usually prewired at the factory. If you
wire the connector, refer to Fig. 8 for the module connector pin
wiring assignments.
4. Install the module in the shelf.
DATA PORT NUMBER
SWITCH
Port 9 (subassembly)
RXD
RTS
TXD
DCD
CTS
BUS A
S17-1
S18-1
S19-1
S20-1
S21-1
BUS B
S17-2
S18-2
S19-2
S20-2
S21-2
BUS C
S17-3
S18-3
S19-3
S20-3
S21-3
BUS D
S17-4
S18-4
S19-4
S20-4
S21-4
BUS E
S17-5
S18-5
S19-5
S20-5
S21-5
BUS F
S17-6
S18-6
S19-6
S20-6
S21-6
DUPLEX ON PORTS 1-8
SWITCH
S22-8 OFF
S22-8 ON
S22-7 OFF
S22-7 ON
S22-6 OFF
S22-6 ON
S22-5 OFF
S22-5 ON
PORT
Port 1
Full-duplex
Half-duplex
Port 2
Full-duplex
Half-duplex
Port 3
Full-duplex
Half-duplex
Port 4
Full-duplex
Half-duplex
SWITCH
S22-4 OFF
S22-4 ON
S22-3 OFF
S22-3 ON
S22-2 OFF
S22-2 ON
S22-1 OFF
S22-1 ON
PORT
Port 5
Full-duplex
Half-duplex
Port 6
Full-duplex
Half-duplex
Port 7
Full-duplex
Half-duplex
Port 8
Full-duplex
Half-duplex