88
Parameter
Function
Working Period
Note:
It is to set the alarm period, it can enable alarm event only during the
period range which has been set.
1. Click “Setup” and the system will pop out the interface of “Working
Period”.
2. It is to set working period according to the following methods:
You can input time numerical value or press the left mouse button to
drag on the setup interface to set.
There are six periods to be set every day, select the check box in front
of the period, and then the period is valid.
Select week number (it selects Sunday by default, if it selects the
whole week, then it means the setup can be applied to the whole
week, you can also select the check box in front of the week number
to implement independent setting for some days).
3. Click “Save” to complete the setup of working period.
Anti-dither
System only memorizes one event during the anti-dither period. The value
ranges from 0s to 100s.
Area
1. Click “Setup” and the system will pop out the interface of “Set Area”.
2. Set the area name, it is to set the valid area of motion detection
according to the actual situation, and it can set its sensitivity and
threshold respectively. The higher the sensitivity is, the easier it is to
trigger motion detect, the smaller the area threshold is, the easier it is
to generate motion detect, the whole video image is the valid area of
the motion detect by default.
Note:
Different colors represent different areas; each area can set different
detection areas.
The red line in the Oscillogram means triggering motion detect, the green
line means not triggering motion detect.
3. Click “Save” to complete area setup.
Record
Check it and so when alarm occurs, system will auto record. You shall set
record period in Storage>Schedule and select auto record in record control
interface.
Record Delay
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
Relay out
Enable alarm activation function. You need to select alarm output port so
that system can activate corresponding alarm device when alarm occurs.
Alarm Delay
System can delay the alarm output for specified time after alarm ended. The
value ranges from 10s to 300s.
Send Email
If you enabled this function, System can send out email to alert you when
alarm occurs and ends. User may set email address in Network>SMTP.
Audio linkage
Check it and the system will play alarm audio file when alarm occurs. Users
can set the recorded or uploaded audio file in “camera setting
>
audio
>
alarm audio”.