background image

HEX NUT

5

) Pull straight 

upwards on 

unlocked Quartz 

Sleeve.

7

) Reverse order for 

reassembly.

Lubricate O-Rings with 

SILICONE GREASE 

before reinserting and 

turning Quartz Sleeve 

to locked position.

6

) To remove bulb, 

grasp bulb at base 

and pull straight 

upwards.

Flex metal tabs on 

socket outward to 

help release bulb.

 

2

) Lift and remove the 

Blue Upper Center Tube 

with Elbow. 

Remove the Elbow.

BULB 

SUPPORT

BULB BASE

LUBRICATE 

METAL 

TABS

ELBOW

UPPER 

CENTER 

TUBE

4

) Turn the Quartz 

Sleeve Removal 

Tool counter-

clockwise approxi-

mately 

1

/

8

 turn until 

it stops. The Quartz 

Sleeve is now 

unlocked.

Quartz Sleeve Removal / Bulb Removal

1

) Disconnect power, 

remove filter cover and 

place upside down on 

a stable surface.

3

) Invert & place Blue Center Tube 

back down over hex nut. It can 

now be used as the removal tool.

Do not use 

petroleum 

based 

lubricants.

INVERT

9

CAUTION!

UPPER 

CENTER 

TUBE 

BECOMES  

QUARTZ 

SLEEVE 

REMOVAL 

TOOL WHEN 

INVERTED.

USE  BLUE QUARTZ SLEEVE REMOVAL 

TOOL TO LOOSEN OR RE-TIGHTEN 

QUARTZ SLEEVE. NEVER FORCE 

QUARTZ SLEEVE WITH BARE HANDS. 

 

The quartz sleeve 

removal tool is 

molded in BLUE 

material. It func-

tions as the Upper 

Center Tube during 

filter operation and 

becomes the 

QUARTZ SLEEVE 

Removal Tool 

when inverted.

SEE BELOW

INVERT

Summary of Contents for PONDMASTER HAMPTON CPF250 Series

Page 1: ...50 05420 84515 05425 84505 CPF1000 PF900 05430 84575 05435 84565 CPF2000 PF1900 05440 84555 05445 84545 PRESSURE FILTER ITEM NO ITEM NO SERIES No UV Clarifier With UV Clarifier Pour afficher les instr...

Page 2: ...bacteria on the surface of the media that converts dissolved toxic nitrogenous waste to harmless compounds When the bacteria are given the proper environment they grow in a thin biofilm on the surface...

Page 3: ...AL ACCESSORIES for use with your pressurized filter A B C PRO SKIMMERS B PRO BIOLOGICAL FILTER AND FALLS A PRESSURIZED FILTER CHECK VALVE Provide an enclosure for the water pump and keep debris away f...

Page 4: ...ump you will need the following items to set up the filter Hoses Maximum11 2 Flexible pressure hose recommended Note that a Valved Bypass must be incorporated into any high volume system with pumps ov...

Page 5: ...NIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING DO NOT REACH REMOVE OR DISASSEMBLE BEFOREYOU DISCONNECT POWER Note that the hose fittings of your pressure filter vary depending on your model...

Page 6: ...Pad fits into the top tray BioMatrix filter ball media is used in the bottom tray or trays depending on your model If your BioMatrix filter ball media is packed in plastic bags empty them evenly into...

Page 7: ...surfaces of cover and filter case clean of any dirt sand or debris before reassembling BLUE LEVER UP Maximum flow MOVE BLUE LEVER DOWN Reduced flow down to no flow Valve closed BLUE LEVER DOWN PIVOT...

Page 8: ...e switch by forcing the micro switch Never look directly at UV bulb the UV rays are harmful to eyes and skin TOP CAP ON OFF UV SWITCH UV INDICATOR LIGHT The UV bulb will need replacing We recommend ch...

Page 9: ...xi mately 1 8 turn until it stops The Quartz Sleeve is now unlocked Quartz Sleeve Removal Bulb Removal 1 Disconnect power remove filter cover and place upside down on a stable surface 3 Invert place B...

Page 10: ...PF1900 A B C D E F G H I J K L M N O P 15430 15440 15451 15456 15470 15471 Picture Reference Only 15427 15428 15415 15425 15420 15420 Picture Reference Only 15480 15481 Picture Reference Only 15475 No...

Page 11: ...ler the manufacturer their representatives or any other parties do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manuf...

Reviews: