background image

6

HOSE ASSEMBLY

Connect hoses from pump 
and to water return as 
shown using stainless steel 
hose clamps (not supplied).  
We recommend using an 
in-line check valve before 
the pump connection.

6

Unpack the Main filter unit.  Open the cover by pulling latches out at bottom then 
pivoting them outward at the top.  Then pull straight up on cover.
If your filter includes the UV Clarifier, carefully lift the cover and check that UV bulb 

is connected to the fixture inside the quartz sleeve. If it has become dislodged 
during shipping see separate sheet included with UV units 
for instructions to access bulb. Carefully place the cover 

aside. 
Debris Filter Media Pad fits into the top tray.
BioMatrix filter ball media is used in the bottom tray or trays 

depending on your model. If your BioMatrix filter ball media 
is packed in plastic bags, empty them evenly into the 
bottom tray(s) and dispose of the bags.

5

SET UP FILTER MEDIA

When finished, replace cover 
paying careful attention to 
align intake / outlet ports with 
molded handle in filter drum.

Close latches - - Clip tops first 
then press bottoms inward.

MOLDED

HANDLE

INTAKE 

and 

OUTLET

IN 

FROM

PUMP

OUT 

 TO 

POND

Once hoses are connected, the filter should be checked with the pump 
running.  Check that hoses are supported well enough to avoid 

stressing the plastic intake and outlet ports once they are weighted 
with water during operation. Supporting the hoses will help prevent 

kinked tubing. Check for leaks and tighten hose clamps if needed.

    

7

 TEST FILTER SET-UP 

Summary of Contents for PONDMASTER HAMPTON CPF250 Series

Page 1: ...50 05420 84515 05425 84505 CPF1000 PF900 05430 84575 05435 84565 CPF2000 PF1900 05440 84555 05445 84545 PRESSURE FILTER ITEM NO ITEM NO SERIES No UV Clarifier With UV Clarifier Pour afficher les instr...

Page 2: ...bacteria on the surface of the media that converts dissolved toxic nitrogenous waste to harmless compounds When the bacteria are given the proper environment they grow in a thin biofilm on the surface...

Page 3: ...AL ACCESSORIES for use with your pressurized filter A B C PRO SKIMMERS B PRO BIOLOGICAL FILTER AND FALLS A PRESSURIZED FILTER CHECK VALVE Provide an enclosure for the water pump and keep debris away f...

Page 4: ...ump you will need the following items to set up the filter Hoses Maximum11 2 Flexible pressure hose recommended Note that a Valved Bypass must be incorporated into any high volume system with pumps ov...

Page 5: ...NIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING DO NOT REACH REMOVE OR DISASSEMBLE BEFOREYOU DISCONNECT POWER Note that the hose fittings of your pressure filter vary depending on your model...

Page 6: ...Pad fits into the top tray BioMatrix filter ball media is used in the bottom tray or trays depending on your model If your BioMatrix filter ball media is packed in plastic bags empty them evenly into...

Page 7: ...surfaces of cover and filter case clean of any dirt sand or debris before reassembling BLUE LEVER UP Maximum flow MOVE BLUE LEVER DOWN Reduced flow down to no flow Valve closed BLUE LEVER DOWN PIVOT...

Page 8: ...e switch by forcing the micro switch Never look directly at UV bulb the UV rays are harmful to eyes and skin TOP CAP ON OFF UV SWITCH UV INDICATOR LIGHT The UV bulb will need replacing We recommend ch...

Page 9: ...xi mately 1 8 turn until it stops The Quartz Sleeve is now unlocked Quartz Sleeve Removal Bulb Removal 1 Disconnect power remove filter cover and place upside down on a stable surface 3 Invert place B...

Page 10: ...PF1900 A B C D E F G H I J K L M N O P 15430 15440 15451 15456 15470 15471 Picture Reference Only 15427 15428 15415 15425 15420 15420 Picture Reference Only 15480 15481 Picture Reference Only 15475 No...

Page 11: ...ler the manufacturer their representatives or any other parties do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manuf...

Reviews: