APP-control v10.x                                           

 9 

SIM-card

Any SIM card is required for the operation of the APP-control (Prepaid or 
subscription).

 9.1 

Inserting the SIM card

Disconnect the power supply from the device

remove the SIM card holder

(Pleas press the „release button“ slightly to release the holder)

insert the SIM card into the holder

push the SIM card into the device

connect the power supply

13 - 32

Summary of Contents for APP-control

Page 1: ...APP Control Version v10 x as of 02 2018 Operating manual ...

Page 2: ...Front view Antenna Status LED Release SIM card SMA connection Rear view Release connector I PIN1 PIN8 GPS LED Release connector II ...

Page 3: ...rting the SIM card 13 10 Inputs and Outputs connector I 14 11 electrical connection 16 11 1 connection to the heater 16 11 2 Connection of ext button 17 12 Accessories connection 18 12 1 External temperature sensor 18 12 2 GPS receiver 18 13 Start up 20 14 Configuration 21 14 1 Table parameter 24 14 2 Configuration with SMS configurator 25 14 3 Configuration with mobile phone 25 14 4 Delete a phon...

Page 4: ......

Page 5: ...cific cable harnesses indoor window antenna Antenna adapter FME to SMA GPS receiver external temperature sensor 5 32 Prior to insertion of the SIM card please deactivate the PIN request and the mailbox and delete all telephone numbers that may be stored The operation of the GSM remote control will require any SIM card which is not included in the scope of delivery ...

Page 6: ...iquids or dust are existing or my exist 3 Intended use The APP control allows the switching of any device per APP SMS or call The APP control is designated for private use and not for commercial purposes The APP control has to be used exclusively according to the instructions of thes operating manual The manufacturer is not liable for damage which are caused by inappropriate use or incorrect opera...

Page 7: ...f hazardous material in devices and components The compliance with the prescribed EMC limit values was confirmed by an independent EMC testing laboratory Our products are recorded in the register for waste electrical equipment and meet the requirements of the relevant applicable CE regulations We confirm the observation of European standards on our devices by the CE marking WEEE Reg No DE 33181931...

Page 8: ...orm a repair 6 Disposal This product must be taken to an official collecting point for disposal You can also give back the product to the manufacturer for ecological disposal 7 Declaration of conformity The device is complying with the EU regulation 2004 108 EG electromagnetic compatibility Applied standards EN 50498 2011 7 1 Typengenehmigung 8 32 E1 10R 058021 This product must kept out from the ...

Page 9: ...put signal Version output BASIC W BUS E BUS PIN 12V 12V 12V 2 ground ground ground 3 12V W BUS 3 E BUS 3 1 W BUS 4 E BUS 4 W BUS 5 E BUS 5 W BUS 6 E BUS 6 E BUS 7 E BUS 8 9 32 The APP control W BUS and E BUS are supporting different output signals An overview about the signal needed for your vehicle or heater can be found at our website www danhag de ...

Page 10: ... version communicates with the heater and can display the current state of the heater 8 1 2 Status messages E BUS only Status messages are deactivated with the default settings When status messages are enabled you will be notified via SMS either when the heater was started successfully the heater could not be started the heater was turned off 10 32 Status messages are not supported from all vehicl...

Page 11: ...s board computer If the operating time can t be queried the default value will be used 8 2 Alarm function The APP control is equipped with an alarm input which can be connected to an existing alarm system After connecting the power supply to the APP control the voltage level on the alarm input will be stored 0 or 12V As soon as this level changes the alarm will be triggered and all stored numbers ...

Page 12: ...witching by APP or SMS You can query the current switching state of the APP control by sending a SMS with the text INFO to the APP control 8 4 Status LED GPS LED Die LEDs zeigen den aktuellen Zustand des Gerätes und des GPS Empfängers an Status LED flashing green every 3s Standby logged in lighting green Heater is switched on flashing red Network search not logged in lighting red fault GPS LED off...

Page 13: ...rol Prepaid or subscription 9 1 Inserting the SIM card Disconnect the power supply from the device remove the SIM card holder Pleas press the release button slightly to release the holder insert the SIM card into the holder push the SIM card into the device connect the power supply 13 32 ...

Page 14: ...mA 4 output GND output GND 1KOhm for ext LED 5 green input 12V Input for ext button switch Button one impulse approx 1s is turning the Switching outputs alternately on and off on for preset time Switch as long as 12V are applied the Switching outputs are activated max for preset time 6 output 12V output 12V for ext Taster 7 red power supply 12V fuse with 5A 8 brown ground Ground connection 9 not i...

Page 15: ... com 12 Relais no 13 blue input alarm 12V GND Input for an existing alarm system see alarm function 14 orange input ignnition 15 32 The inputs and outputs marked with must be connected for the basic functionality of the device All further connections can be used optionally ...

Page 16: ... 2 heater with radio remote control The APP control is connected to the already existing receiver of the remote control using the y cable which is included into delivery The Y cable also ensures the power supply of the APP control disconnect the original cable from the receiver connect the y cable to the receiver connect the original cable to the y cable connect the APP control to the Y cable 16 3...

Page 17: ...sistor integrated to drive a LED directly 11 2 1 Difference between button and switch Button Pressing the button shortly approx 1s will switch on the heater for the preset time If you want to switch of the heater you have to press the button once again Switch The heater is running as long as the switch is closed but max for the preseted time 17 32 white green brown DANHAG button 14pol connector of...

Page 18: ...orts an external GPS receiver which can be connected to the aux socket at the back of the module If the ignition is switched on the position is determined about every 1 second and can be queried via SMS If the ignition is switched off the GPS receiver is activated during determining the position only You will get a SMS containing the current coordinates of the car as well as a link to google maps ...

Page 19: ...GPS receiver must be activated when used for the first time Please refer to the manual delivered with the GPS receiver If you want to update the position when the ignition is turned off you will have to send a SMS with the text XGPS to the APP control The GPS receiver is turned on for about 3 minutes and determines the current position If the receiver doesn t get any valid information the last kno...

Page 20: ...upply the APP control will perform a selftest The LED will be lighting red for approx 4 seconds and then begins to flash red network search As soon as the APP control is logged in into the GSM network the LED will be flashing green Now the APP control is ready to operate and can be configured 20 32 Please deactivate the PIN query prior to the insertion of the SIM card Otherwise the APP control can...

Page 21: ...tion you will need the 5 digit password the password can be modified and must consist of 5 figures preset 12345 after a reset the password will be set back to 12345 Running time Determines how long the heater is switched on To configure an impulse set the runntime to 0 minutes 2 seconds 21 32 The maximum run time is limited internally to about 30 or 60 minutes at some heaters Regardless of the con...

Page 22: ...taneously with output 1 You can configure a switch off delay so output 2 and 3 will be switched off after output 1 Output signal Basic W BUS E BUS Determines the outputsignal on pin 1 yellow wire Alarm delay Determines how long the alarm signal must be present continuously before the alarm is triggered 22 32 The switch on delay is supported from output 2 only The switch off delay is supported from...

Page 23: ...l Status notification Determines if and which status reports will be sent by the GSM remote control 0 all status reports deactivated 1 only fault messages 2 only switch on messages 4 only switch off messages 23 32 Please enter the phone number with the international prefix e g 49 for germany The phone number must not exceed 17 digits in total If you want to be informed about several events you hav...

Page 24: ...43 e g 49171345678 12 Phone number 2 13 Phone number 3 14 Phone number 4 15 Phone number 5 20 Running time 10 255 Running time in Minutes 21 Switch on delay 0 255 Minutes not E BUS 22 Switch off delay 0 255 Minutes not E BUS 23 Running time 0 59 Seconds 30 Outputsignal 1 8 33 Status notification 0 7 35 Ext temp Sensor 0 1 0 not connected 1 connected 40 Alarm delay 0 251 sek 251 alarm deactivated 2...

Page 25: ... setting has an assigned number The assignment of the respective parameter is carried out by a sign Close up each input with a You can summarize several functions in one SMS max 150 digits Finish the configurations SMS with Example SMS The example SMS configures the GSM remote control as follows Masternumber 1 0305627853 Phone number 2 01706878981 Running time 25 minutes Syntax 12345 11 4930562785...

Page 26: ...40 50 60 OFF switches the heater off START0630 Timer function e g heater starts at 6 30 am STOP switches the heater off and deletes the timer GPS Query of the last known GPS position1 XGPS Query of the current GPS position1 1 GPS receiver required 26 32 If you use an APP for controlling the heating it also sends the corresponding SMS commands in the background Depending on your mobile phone contra...

Page 27: ...ve an SMS with a summary of the settings to the master number 27 32 Status Status of heater on remaining time off running time Timer Preset start time Alarm Alarm delay Signal Field strength 0 31 10 bad 31 good Info Status notifications PWD Current password SW Software version DANHAG Status off 20min Timer off Alarm 3s Signal 21 Temp ext INFO 7 PWD 12345 SW v10 x ...

Page 28: ... fuse 5A No switching operation at all Not incorrectly configured Phone number existing twice on SIM card APP control not configured yet delete all phone numbers SMS on SIM cardand re configure No INFO SMS query possible Kno credit on SIM card of APP control Load credit Heater is not running during preset timet Under voltage on heater or maximum heating time achieved Check vehicle battery APP cont...

Page 29: ...ight All brands and trademarks mentioned in this operation manual and possibly protected by third parties are unlimitedly subject to the regulations of the respectively valid trademark law of the respectively registered owners The bare mentioning does not allow the conclusion that brands are not protected by rights of third persons The brands and trademarks mentioned in this operation manual are p...

Page 30: ...APP control v10 x 19 Installation location Mark the installation location of the APP control 30 32 ...

Page 31: ......

Page 32: ...Please visit www danhag de for an german version of this users guide 740409 740409 ...

Reviews: