These instructions pertain to the VLZ028-
VLZ044 variable scroll compressors used for air-
conditioning and reversible heat pump systems 
in residential applications. They provide neces-
sary information regarding safety and proper us-
age of this product.

2 – Handling and storage

 •  Handle the compressor with care. Use the dedi-

cated handles in the packaging. Use the com-
pressor lifting lug and use appropriate and safe 
lifting equipment.

 •  Store and transport the compressor in an up-

right position.

 •  Store the compressor between -35°C and 55°C 

/ -31°F and 131°F.

 •  Don’t expose the compressor and the packag-

ing to rain or corrosive atmosphere.

3 – Safety measures before assembly

Never use the compressor in a flammable at-

mosphere.
 •  The compressor ambient temperature may
not exceed 55°C during off-cycle.
 •  Mount the compressor on a horizontal flat sur-

face with less than 7° slope.

 •  When installing a compressor model VLZ, use 

equipment specifically reserved for HFC refrig-
erants, which was never used for CFC or HCFC 
refrigerants.

 •  Use clean and dehydrated refrigeration-grade 

copper tubes and silver alloy brazing material.

 •  Use clean and dehydrated system components.
 •  The piping connected to the compressor must 

be flexible in 3 dimensions to dampen vibra-
tions.

 •  The compressor must always be mounted using 

the rubber grommets supplied with the com-
pressor.

4 – Assembly

 •  Slowly release the nitrogen holding charge 

through discharge and suction ports.

 •  Connect the compressor to the system as soon 

as possible to avoid oil contamination from 
ambient moisture.

 •  Avoid material entering into the system while 

cutting tubes. Never drill holes where burrs 
cannot be removed.

 •  Braze with great care using state-of-the-art 

technique and vent piping with nitrogen gas 
flow.

 •  Connect the required safety and control de-

vices. 

5 – Leak detection

 Never pressurize the circuit with oxygen or 

dry air. This could cause fire or explosion.
 •  Do not use leak detection dye.
 •  Perform a leak detection test on the complete sys-

tem.

 •  The low side test pressure must not exceed  

31 bar /450 psi.

 •  When a leak is discovered, repair the leak and 

repeat the leak detection.

6 – Vacuum dehydration

 •  Never use the compressor to evacuate the sys-

tem.

 •  Connect a vacuum pump to both the LP & HP sides.
 •  Pull down the system under a vacuum of 500 

µm Hg (0.67 mbar) / 0.02 inch Hg absolute.

 •  Do not use a mega ohmmeter nor apply power 

to the compressor while it is under vacuum as 
this may cause internal damage.

7 – Electrical connections

 •  Switch off and isolate the main power supply.
 •  Before touching any potentially live part of the 

drive, wait at least 4 minutes.

 •  The compressor is protected against excess 

current by the frequency converter. Follow lo-
cal regulations regarding power line protec-
tion.The compressor must be connected to 
ground.

 •  Use 6.3 mm tabs for quick connect spade ter-

minals.

 •  Use a self-tapping screw to connect the ground 

conductor to the compressor.

 •  

Care must be taken during installation to 
ensure that the compressor operates in the 
correct direction. T1 (U), T2 (V) and T3 (W) ter-
minals of compressor and drive U, V, W must 
match. Please refer to drawings for typical wir-
ing connections and examine the specific wir-
ing diagram located in the frequency converter 
package. For further details, refer to the appli-
cation guidelines.

 •  Mounting: The base frame of the frequency 

converter must be very well fixed to the sup-
port to ensure a very good continuity between 
the ground potential of all electrical panels and 
electrical boxes of the system.

 •  

Wiring: All control wires have to be of a 
screeened design. The cable for electrical mo-
tor supply has to be of a shielded design as 
well. Correct earthing of the shield cover has to 
be done using the method shown on drawings, 
every time this one has to be earthed on each 
end of the cables. Distinct cable trays must be 
used for control and motor supply.

• The frequency converter ensures direct motor 
protection and the factory set parameters are 
such to protect the motor over all current mal-
functions.
An external overload is not necessary.
• Set the frequency converter parameters in
accordance with Danfoss recommendations
for the CDS803 frequency converter and VLZ
variable speed compressor.
 •  Refer to variable speed drive manual for electri-

cal connections details and installation.

 •  Compressor motor protection is provided by 

the variable speed drive. 

8 – Filling the system

 •  Keep the compressor switched off.
 •  Fill the refrigerant in liquid phase into the 

outlet of the condenser or the liquid receiver. 
The charge must be as closed as possible to 
the nominal system charge to avoid low pres-
sure operation and excessive superheat. For 
VLZ028-044, the refrigerant charge limit is 
3.6kg.Above this limit; protect the compressor 
against liquid flood-back with a pump-down 
cycle not lower than 1.1 bar(g) for R448A/1.1 
bar(g) for R449A/ 1.6 bar(g) for R404A or a suc-
tion line accumulator.

 •  Never leave the filling cylinder connected to 

the circuit.

9 – Verification before commissioning

 Use safety devices such as safety pressure 

switch and mechanical relief valve in compli-
ance with both generally and locally applicable 
regulations and safety standards. Ensure that 
they are operational and properly set. 

 Check that the settings of high-pressure 

switches do not exceed the maximum service 
pressure of any system component.
•  A low-pressure switch is mandatory to avoid 

vacuum operation. 

Refrigerant

R448A R449A R404A

Min. low pressure 

safety switch setting

bar(g) 0.8

0.8

1.3

 •  Verify that all electrical connections are prop-

erly fastened and in compliance with local 
regulations.

 •  When using a dome sensor, ensure the dome 

sensor is correctly installed and fitted into 
bracket on top of the shell. The sensor need 
to be well connected, especially after mainte-
nance operations.

 •  After comissioning it is strongly recommended 

to keep the frequency converter always ener-
gized.

10 – Start-up

 •  Never start the compressor when no refriger-

ant is charged.

 •  Do not provide any power to the drive unless 

suction and discharge service valves on com-
pressor are open, if installed.

 •  Energize the drive. The compressor must start, 

according to defined ramp-up settings. If the 
compressor does not start, check wiring con-
formity.

 •  Check the frequency converter control panel: 

If any alarm is displayed check the wiring and 
in particular the polarity of the control cables. 
If an alarm is shown, refer to the frequency 
converter application manual. Verify in particu-
lar the combination of compressor, frequency 
converter and refrigerant.

Instructions

© Danfoss | DCS (CC) | 2017.07  | 3

8510286P01B - FRCC.PI.039.A3.02

Summary of Contents for VZL028

Page 1: ... under nitrogen gas pressure between 0 3 and 0 4 bar 4 and 6 psi Do not disassemble bolts plugs fittings etc unless all pressure has been relieved from the compressor A B C D E F G H Operating limits Quick connect spade terminals push push push Electrical connections All the above limits temperatures and speeds are secured by parameters in the drive and application controller softwares VLZ028 VLZ0...

Page 2: ...O 05 12 24 V OUT COM 04 18 DIGI IN 19 DIGI IN 27 DIGI IN 29 DIGI IN 20 COM D IN N RS 485 69 P RS 485 68 Com RS 485 61 RELAY 2 CDS803 Legends Ana Analogue Dig Digital in Input out Output COM Common NC Normally closed NO Normally open Open loop Process loop 91 92 93 3 phases mains input x x 95 Earth x x 42 45 0 4 20 mA Analague Output or Digital Output 50 10V DC Output 53 0 10V or 4 20mA Analague In...

Page 3: ... located in the frequency converter package For further details refer to the appli cation guidelines Mounting The base frame of the frequency converter must be very well fixed to the sup port to ensure a very good continuity between the ground potential of all electrical panels and electrical boxes of the system Wiring All control wires have to be of a screeened design The cable for electrical mo ...

Page 4: ...s coil cleanliness fan opera tions water flow water filter etc liquid refrig erant flow and pressure drops solenoid valve filter dryer expansion valve etc refrigerant charge Low refrigerant charge The correct refrigerant charge is given by the liquid sight glass indica tion the condenser delta T in relation to the refrigerant pressure tables pressure tempera ture the superheat and the sub cooling ...

Reviews: