background image

1.
2.
3.
4.

-

1 Instructions

1.1 Safety and Installation Awareness

Before starting installation, read and understand this installation guide while paying attention to all safety guidelines and precau-
tions. Additional documentation can be accessed by scanning the QR code on the front cover. MyDrive

®

 ecoSmart

 and pc tools

can be downloaded at 

www.danfoss.com

.

1.2 Compatible Product Series

Table 1: Compatible Product Series

Option

FC 302

FCD 302

VLT® Safety Option MCB 150

X

VLT® Safety Option MCB 151

X

VLT® Safety Option MCB 152

X

X

1.3 Installing the Option

N O T I C E

Place the VLT® AutomationDrive FC 302 with safety option (including connection between S37 (terminal 12) on the VLT® Safety
Option MCB 15x and terminal 37 on the control card) in an IP54 enclosure as per IEC 60529.

N O T I C E

VLT® SAFETY OPTION MCB 152 IN VLT® DECENTRAL DRIVE FCD 302

The VLT® Safety Option MCB 152 is only available factory-mounted for the VLT® Decentral Drive FCD 302. Thus, there is only elec-
trical installation required when using the option in this drive.

Procedure

Disconnect power from the drive.
Remove the LCP, the terminal cover, and the LCP frame from the drive.
Write down the serial number and order number of the safety option for use during the commissioning process.
Fit the safety option in slot B. See the location of the option slots in section 1 in the 

Illustrations

 section.

When a drive is ordered with a safety option, the option is factory mounted in the drive. The only action needed is the
following:

Remove the jumper wire between T12/13 and T37 and connect S37 (T12 from safety option) to T37 for STO function-
ality.

Connect wires to the terminals of the option according to the need of the setup.

1.4 Cabling Requirements

C A U T I O N

If a short circuit occurs, it is no longer possible to switch off the drive with terminal 37.

N O T I C E

All signals to the safety option must be PELV supplied and comply with EN IEC 60204.

Follow these guidelines to ensure proper wiring:

AN42452894295101-000101/

130R1272 

 | 5

Danfoss A/S © 2022.09

Instructions

VLT® Safety Options MCB 150, MCB 151, MCB 152

Installation Guide

American English

Summary of Contents for VLT Safety Option MCB 150

Page 1: ...Scan to access more documentation Installation Guide Installationshandbuch Guida di installazione Manuel d installation VLT Safety Options MCB 150 MCB 151 MCB 152 vlt drives danfoss com...

Page 2: ......

Page 3: ...1 2 3 4 Languages American English 5 German 6 Italian 8 French 10 AN42452894295101 000101 130R1272 3 Danfoss A S 2022 09 Languages Installation Guide VLT Safety Options MCB 150 MCB 151 MCB 152...

Page 4: ...AN42452894295101 000101 130R1272 4 Danfoss A S 2022 09 Installation Guide VLT Safety Options MCB 150 MCB 151 MCB 152 Languages...

Page 5: ...s only elec trical installation required when using the option in this drive Procedure Disconnect power from the drive Remove the LCP the terminal cover and the LCP frame from the drive Write down the...

Page 6: ...maximum length of this wire is 100 mm 3 9 in For FCD 302 connect terminal B12 safe output S37 on the safety option to terminal 37 on the terminal block Section 2 in the Illustrations section shows th...

Page 7: ...men der Option an 1 4 Verkabelungsanforderungen V O R S I C H T Bei Kurzschl ssen ist es nicht mehr m glich die Klemme 37 des Frequenzumrichters abzuschalten H I N W E I S Alle Signale zur Sicherheits...

Page 8: ...indabdeckung an der Frontabdeckung des LCP an Schlie en Sie die Netzversorgung am Frequenzumrichter an 1 Istruzioni 1 1 Consapevolezza in materia di sicurezza e installazione Prima di iniziare l insta...

Page 9: ...dibile che si verifichino cortocircuiti e cortocircuiti trasversali con segnali di sicurezza e se questi non vengono rilevati dai dispositivi a monte necessaria una posa dei cavi protetta secondo la n...

Page 10: ...uent seule une installation lectrique est n cessaire lors de l utilisation de l option dans ce variateur Proc dure Mettre le variateur hors tension Retirer le LCP la protection borniers et le ch ssis...

Page 11: ...tion de s curit se reporter au Guide d installation du VLT Safety Option MCB 150 151 ou du VLT Safety Option MCB 152 Proc dure Retirer le fil cavalier entre les bornes de commande 37 et 12 13 24 V La...

Page 12: ...2 Illustrations Abbildungen Illustrazioni Illustrations e30bj461 10 LCP frame A slot B slot D slot 1 VLT Safety Options MCB 150 MCB 151 MCB 152 AN42452894295101 000101 130R1272 12 Danfoss A S 2022 09...

Page 13: ...2 e30bk274 10 FCD 302 FC 302 2A e30bk263 10 VLT Safety Options MCB 150 MCB 151 MCB 152 AN42452894295101 000101 130R1272 13 Danfoss A S 2022 09...

Page 14: ...VLT Safety Options MCB 150 MCB 151 MCB 152 AN42452894295101 000101 130R1272 10 Danfoss A S 2022 09...

Page 15: ......

Page 16: ...rinted material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes...

Reviews: