LCP message
Description
130BD126.10
Status
SO Reset required!
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
In the following cases, the
safety option requests a
restart and failure acknowl-
edgement-signal:
1. The safety option is in
safety function pending-
state (Remark: Occurs only
if reset behaviour is set/
configured to ‘manual’)
2. After a power cycle with a
safety function
3. In PUST (power up self
test), if an external failure
occurred before power
cycle
4. When an external failure
occurred
5. When customisation was
aborted or completed
6. At the reception of a
general reset (required
after blank initial state or
in the customisation
state.)
130BD127.10
Status
SO in Self-test
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
The safety option indicates
that it is PUST State (Power
Up Self Test).
1. Ensure that no safe
function is active after a
power cycle.
130BD128.10
Status
SF pending
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
A safety function is pending
at the start-up, if the
frequency converter was
powered down while a safety
function was active.
It is also pending, when the
frequency converter was
powered down while the
safety option has detected a
failure during an active safety
function.
130BD129.10
Status
SafeOpt. initialised
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
The safety option requests a
‘Restart and Failure
Acknowledge signal’, which is
always required after a PUST
and when a safety function
gets released and is
configured to be confirmed
that the motor is able to run.
LCP message
Description
130BD130.10
Status
SO General Reset
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
Occurs only if general reset is
performed from MCT 10. It is
an indication to the user. The
safety option is set to blank
initial state and safe
parameters are set to default.
130BD131.10
Status
SO Suspend-SpeedMon
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
Zero speed timer contains
the remaining time until the
fail prec thresh timer elapsed
after the monitoring time
expires. The safety option
signals Warning.
130BD132.10
Status
SO Warning PUST
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
PUST warning has occurred.
Warning cause: Expiry of
PUST timer. Memory test
required, perform power
cycle.
130BD133.10
Status
SO Warning DI1
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
DI1 offline warning has
occurred.
Warning cause: Expiry of
offline timer for DI1.
130BD134.10
Status
SO Warning DI2
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
DI2 offline warning has
occurred.
Warning cause: Expiry of
offline timer for DI2.
130BD131.10
Status
SO Suspend-SpeedMon
!1(1)
0 RPM None 0.00KW
!Safe Stop [W68]
Speed monitoring suspension
warning has occurred.
Warning cause: Suspension of
speed monitoring for certain
duration.
Table 8.3 LCP Messages
Warnings and Alarms
Operating Instructions
MG34W302