![Danfoss VLT PROFIBUS DP MCA 101 Programming Manual Download Page 39](http://html1.mh-extra.com/html/danfoss/vlt-profibus-dp-mca-101/vlt-profibus-dp-mca-101_programming-manual_3708540039.webp)
9-16 PCD Read Configuration
[10] Array
Option:
Function:
[1665] Analog Output 42 [mA]
[1666] Digital Output [bin]
[1667] Freq. Input #29 [Hz]
[1668] Freq. Input #33 [Hz]
[1669] Pulse Output #27 [Hz]
[1670] Pulse Output #29 [Hz]
[1671] Relay Output [bin]
[1672] Counter A
[1673] Counter B
[1674] Prec. Stop Counter
[1675] Analog In X30/11
[1676] Analog In X30/12
[1677] Analog Out X30/8 [mA]
[1678] Analog Out X45/1 [mA]
[1679] Analog Out X45/3 [mA]
[1684] Comm. Option STW
[1687] Bus Readout Alarm/Warning
[1689] Configurable Alarm/Warning Word
[1690] Alarm Word
[1691] Alarm Word 2
[1692] Warning Word
[1693] Warning Word 2
[1694] Ext. Status Word
[1836] Analog Input X48/2 [mA]
[1837] Temp. Input X48/4
[1838] Temp. Input X48/7
[1839] Temp. Input X48/10
[1860] Digital Input 2
9-18 Node Address
Range:
Function:
126
*
[ 0 -
126 ]
Enter the station address in this parameter or
alternatively in the hardware switch. In order to
adjust the station address in
, the hardware switch must be set to 126
or 127 (that is, all switches set to ‘on’). Otherwise
this parameter displays the actual setting of the
switch.
9-22 Telegram Selection
Option:
Function:
Select a standard PROFIBUS
telegram configuration for the
frequency converter, as an
alternative to using the freely
configurable telegrams in
9-15 PCD
Write Configuration
and
9-16 PCD
Read Configuration
.
[1]
Standard telegram 1
[101]
PPO 1
[102]
PPO 2
9-22 Telegram Selection
Option:
Function:
[103]
PPO 3
[104]
PPO 4
[105]
PPO 5
[106]
PPO 6
[107]
PPO 7
[108]
*
PPO 8
9-23 Parameters for Signals
Array [1000]
Read only
Option:
Function:
This parameter
contains a list of
signals available for
selection in
parameter 9-15 PCD
Write Configuration
and
parameter 9-16 PCD
Read Configuration
.
[0]
*
None
[15]
Readout: actual setup
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[412]
Motor Speed Low Limit [Hz]
[413]
Motor Speed High Limit [RPM]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus Control
[615]
Terminal 53 High Ref./Feedb. Value
[625]
Terminal 54 High Ref./Feedb. Value
[653]
Term 42 Output Bus Ctrl
[663]
Terminal X30/8 Bus Control
[673]
Terminal X45/1 Bus Control
[683]
Terminal X45/3 Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
Parameters
Programming Guide
MG37G102
Danfoss A/S © Rev. 05/2014 All rights reserved.