background image

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to

products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property

of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss A/S

Ulsnaes 1

DK-6300 Graasten

vlt-drives.danfoss.com

 

*MG33C602*

130R0302

MG33C602

07/2015

Summary of Contents for VLT PROFIBUS DP MCA 101

Page 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide VLT PROFIBUS DP MCA 101 VLT Frequency Converter FC 102 FC 103 FC 202 FC 301 302 FCP 106 FCM 106 vlt drives danfoss com...

Page 2: ......

Page 3: ...3 4 Cable Routing 6 3 5 Mounting 6 3 5 1 Mounting in an FC Series Frequency Converter 6 3 5 2 Mounting in a VLT DriveMotor FCP 106 Frequency Converter 8 3 6 Setting Address Switches 8 3 7 Electrical...

Page 4: ...om Danfoss See vlt drives danfoss com Support Technical Documentation for listings 1 3 Product Overview 1 3 1 Intended Use This installation guide relates to PROFIBUS interface ordering numbers 130B11...

Page 5: ...High frequency LCP Local control panel LED Light emitting diode LOP Local operating panel PC Personal computer PLC Programmable logic control PPO Parameter process data STW Status word Table 1 1 Symbo...

Page 6: ...r load sharing the motor may start at any time Unintended start during programming service or repair work can result in death serious injury or property damage The motor can start with an external swi...

Page 7: ...ectrical work conforms to national and local electrical codes Follow the procedures in this manual CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious...

Page 8: ...te cables for fieldbus communication motor wiring and brake resistor Failure to isolate fieldbus communication motor and brake resistor cables can result in unintended behaviour or reduced performance...

Page 9: ...1 LCP 2 LCP cradle 3 VLT PROFIBUS DP MCA 101 option card 4 Connector plug Illustration 3 2 Exploded View 130BD862 10 Illustration 3 3 Top Cable Entry Option Mounted with Connector Facing Up 130BD863...

Page 10: ...ted in FCP 106 3 6 Setting Address Switches Set the address switches to give the option a unique ID Select an address range from 0 125 factory setting 127 according to Table 3 1 Switch 8 7 6 5 4 3 2 1...

Page 11: ...on switch When the D sub 9 adapter is used set the termination switch on the fieldbus option to OFF to avoid double termination NOTICE When the fieldbus is extended with a repeater terminate the exten...

Page 12: ...Segment Transmission speed 1 segment m 2 segments m 3 segments m 4 segments m 9 6 187 5 kBaud 1000 2000 3000 4000 500 kBaud 400 800 1200 1600 1 5 MBaud 200 400 600 800 3 12 MBaud 100 200 300 400 Tabl...

Page 13: ...Connect the fieldbus cable wires to the terminals according to the colour code of the wires see Illustration 3 10 4 To establish mechanical fixation and electrical contact between cable screen and gr...

Page 14: ...3 11 Wiring for Enclosure Sizes A4 A5 B1 B4 and C1 C4 Wiring procedure for enclosure sizes D E and F 1 Mount the fieldbus connector on the fieldbus option terminals 62 63 66 and 67 2 Prepare the field...

Page 15: ...06 MH1 MH3 3 8 Reassembling Cover 1 Mount the new front cover and the LCP 2 Attach the sticker with the correct product name to the front cover 3 9 Applying Power Follow the instructions in the freque...

Page 16: ...search 00000040 166 PROFIBUS ASIC is not transmitting 00000080 167 Initialising of PROFIBUS is not OK 00000100 152 Drive is tripped 00000200 153 Internal CAN error 00000400 154 Wrong configuration da...

Page 17: ...ation from a master class 1 PLC is active Green Long green flash DP V1 communication from a master class 2 MCT 10 FDT is active Green Solid green DP V1 communication from a master class 1 and 2 is act...

Page 18: ...t installation 6 Exploded view 7 G Grounding 6 H High voltage 4 I Installation electrical 9 Intended use 2 Items supplied 2 L Leakage current 4 LED panel 14 LED status 14 Load sharing 4 M MCT 10 2 Mod...

Page 19: ...Index Installation Guide MG33C602 Danfoss A S 07 2015 All rights reserved 17...

Page 20: ...ucts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the resp...

Reviews: