![Danfoss VLT OneGearDrive Instruction Manual Download Page 10](http://html1.mh-extra.com/html/danfoss/vlt-onegeardrive/vlt-onegeardrive_instruction-manual_3531470010.webp)
Take care when fitting transmission elements onto the
hollow shaft of the OneGearDrive, which is finished to ISO
H7. Use the tapped end hole intended for this purpose
according to DIN 332.
The maximum force based on bearing life is detailed in
(
and
130BD895.10
F
Rzul
X
0
Figure 3.1 Maximum Force
Up to n2
[RPM]
F
RZUL
[N] up to X (in [mm])
1)
0.98
[25]
1.97
[50]
2.95
[75]
3.94
[100]
4.92
[125]
50
170
[4319]
148.2
[3763]
131.3
[3335]
117.9
[2994]
106.9
[2716]
100
119
[3023]
103.7
[2634]
91.9
[2334]
82.5
[2096]
74.8
[1901]
200
68
[1727]
59.3
[1505]
52.5
[1334]
47.2
[1198]
42.8
[1086]
360
55.3
[1404]
48.2
[1223]
42.8
[1084]
38.3
[973]
34.8
[883]
Table 3.1 Maximum Force
1) X is the distance from the surface of the hollow shaft to the force
location.
3.5.1 Mounting Procedure
1.
Fasten the drive unit by its flange using the
torque arm (see
2.
Attach the OneGearDrive on to the driven shaft
using the means provided.
3.6 Assembly Kit
6
1
3
2
4 5
Holding
130BC006.11
1
Shaft
2
Disc
3
Retaining ring
4
Lock washer
5
Fixing screw (filister head)
6
Key
Figure 3.2 Assembly Kit
Mechanical Installation
Instruction Manual
8
Danfoss A/S © 08/2014 All rights reserved.
MG75C422
3
3