9.3.11 AUX user limit current (0x2393 / 0x127)
This error is valid for DAM 510.
Table 46: AUX user limit current (0x2393 / 0x127)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2393
0x127
AUX user limit
current
Error
Current on the AUX line has reached
the user-defined limit for fault.
AUX curr limit
9.3.12 AUX user limit current warning (0x2394 / 0x128)
This error is valid for PSM 510 and DAM 510.
Table 47: AUX user limit current warning (0x2394 / 0x128)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2394
0x128
AUX user limit cur-
rent warning
Warning
Current on the AUX line has reached
the user-defined limit for warning.
AUX curr
warn
9.3.13 AUX fuse failure (0x2395 / 0x129)
This error is valid for DAM 510.
Table 48: AUX fuse failure (0x2395 / 0x129)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x2395
0x129
AUX fuse fail-
ure
Error
Fuse failure. Current or voltage is above
the limit on the AUX line.
AUX fuse fail
9.3.14 DC overcurrent trip (0x2396 / 0x15C)
This error is valid for DAM 510 and SDM 511/SDM 512.
Table 49: DC overcurrent trip (0x2396 / 0x15C)
Code
PROFINET
®
code
Name
Severity (warning/error/trip lock)
Description
LCP name
0x2396
0x15C
DC Overcurrent trip
Error
DC overcurrent trip.
overcurr trip
9.3.15 Output power trip (0x2397 / 0x12B)
This error is valid for PSM 510.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
174 | Danfoss A/S © 2019.10