3.4.1.3 Terminals

There are 3 inputs and 3 outputs on the option:

Inputs: X49/1+2, X49/3+4, and X49/5+6

Outputs: X49/7+8, X49/9+10, and X49/11+12

e3

0b

t1

25

.1

2

IN

1

1

G

N

D

2

IN

2

3

G

N

D

4

IN

3

5

G

N

D

6

O

U

T1

7

G

N

D

8

O

U

T2

9

G

N

D

10

O

U

T3

11

G

N

D

12

MCB 115

OPTION B

Programmable I/O

130B1266

X49/

SW. ver.  xx.xx

Illustration 4:  Terminal X49

Installation

Installation Guide  | VLT® Programmable I/O MCB 115

AN295938195323en-000101 / 130R0655| 13

Danfoss A/S © 2020.01

Summary of Contents for VLT MCB 115

Page 1: ...Installation Guide VLT Programmable I O MCB 115 VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT AutomationDrive FC 301 302...

Page 2: ......

Page 3: ...3 Safety Precautions 7 3 Installation 8 3 1 Safety Instructions 8 3 2 Mounting the Option in Enclosure Sizes A2 A3 and B3 8 3 3 Mounting the Option in Enclosure Sizes A5 B1 B2 B4 C D E and F 9 3 4 Ele...

Page 4: ...f this manual is English Table 1 Version and Changes Applied Revision date Remarks 2019 10 Option now also applicable for VLT HVAC Drive FC 102 and VLT Refrigeration Drive FC 103 1 4 Additional Resour...

Page 5: ...VLT AutomationDrive FC 301 VLT AutomationDrive FC 302 NOTICE The VLT Programmable I O MCB 115 is only functional if it is built into the drive The option cannot be used as a standalone 1 5 2 Foreseeab...

Page 6: ...ned maintained and decommissioned by persons with proven skills Persons with proven skills Are qualified electrical engineers or persons who have received training from qualified electrical engineers...

Page 7: ...programming parameters Disconnect the drive from the mains whenever personal safety considerations make it necessary to avoid unintended motor start Check that the drive motor and any driven equipmen...

Page 8: ...he drive or performing any work on the cables WARNING BEFORE INSTALLATION REPAIR The operator or electrical installer is responsible for compliance with all applicable national and local safety regula...

Page 9: ...me 7 Connect power to the drive 8 Set up the input output functions in the corresponding parameters e30be183 11 1 2 5 4 3 1 LCP 3 Slot B 5 LCP frame 2 Terminal cover 4 Option Illustration 1 Installati...

Page 10: ...it the LCP in the cradle 1 2 3 4 e30be184 11 Illustration 2 Installation in Enclosure Sizes A5 B1 B2 B4 C D E and F 3 4 Electrical Installation 3 4 1 Specifications The VLT Programmable I O MCB 115 ha...

Page 11: ...Block Diagram 3 4 1 1 Programmable Inputs The analog inputs can be used for reference or process feedback for PID controllers They can work as Analog voltage inputs Analog current inputs Analog temper...

Page 12: ...impedance low as every 3 85 in cables gives a misreading of 1 Kelvin 3 4 1 2 Programmable Outputs The 3 programmable outputs can work as analog voltage outputs analog current outputs digital outputs...

Page 13: ...49 9 10 and X49 11 12 e30bt125 12 IN1 1 GND 2 IN2 3 GND 4 IN3 5 GND 6 OUT1 7 GND 8 OUT2 9 GND 10 OUT3 11 GND 12 MCB 115 OPTION B Programmable I O 130B1266 X49 SW ver xx xx Illustration 4 Terminal X49...

Page 14: ...of the information is not relevant Bolded text indicates highlighting and section headings Italicized text indicates the following Cross reference Link Footnote Parameter name Parameter option Parame...

Page 15: ...Installation Guide VLT Programmable I O MCB 115 AN295938195323en 000101 130R0655 15 Danfoss A S 2020 01...

Page 16: ...der provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies D...

Reviews: