background image

e3

0b

b4

20

.1

1

Control card (drive)

0 V

CPU

CPU

24 V DC

Programmable I/O

option MCB 115

CA

N

 b

us

Analog input

Analog/digital

A

IN

A

IN

A

IN

A

O

U

T

A

O

U

T

A

O

U

T

G

N

D

D

O

U

T

D

O

U

T

D

O

U

T

1

2

3

4

5

6

7

8

9

10

11

12

0–10

V DC

0–20

mA

0–10

V DC

0–20

mA

0–10

V DC

0–20

mA

0–1

D

C/

0–2

m

A

0–1

D

C/

20

 m

A

Pt1000/

Ni 1000

D

O

U

T

D

O

U

T

D

O

U

T

X49/

0–1

D

C/

20

 m

A

Illustration 3:  Input and Output Block Diagram

3.4.1.1 Programmable Inputs

The analog inputs can be used for reference or process feedback for PID controllers. They can work as:

Analog voltage inputs.

Analog current inputs.

Analog temperature inputs.

Table 2: Programmable Inputs

Used as temperature sensor

input

Used as analog voltage

input

Used as current input

Number of inputs

3

3

3

Terminal

X49/1–6

X49/1–6

X49/1–6

Voltage/current range

0–10 V DC or 2–10 V DC

0–20 mA or 4–20 mA

Installation

Installation Guide  | VLT® Programmable I/O MCB 115

AN295938195323en-000101 / 130R0655| 11

Danfoss A/S © 2020.01

Summary of Contents for VLT MCB 115

Page 1: ...Installation Guide VLT Programmable I O MCB 115 VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT AutomationDrive FC 301 302...

Page 2: ......

Page 3: ...3 Safety Precautions 7 3 Installation 8 3 1 Safety Instructions 8 3 2 Mounting the Option in Enclosure Sizes A2 A3 and B3 8 3 3 Mounting the Option in Enclosure Sizes A5 B1 B2 B4 C D E and F 9 3 4 Ele...

Page 4: ...f this manual is English Table 1 Version and Changes Applied Revision date Remarks 2019 10 Option now also applicable for VLT HVAC Drive FC 102 and VLT Refrigeration Drive FC 103 1 4 Additional Resour...

Page 5: ...VLT AutomationDrive FC 301 VLT AutomationDrive FC 302 NOTICE The VLT Programmable I O MCB 115 is only functional if it is built into the drive The option cannot be used as a standalone 1 5 2 Foreseeab...

Page 6: ...ned maintained and decommissioned by persons with proven skills Persons with proven skills Are qualified electrical engineers or persons who have received training from qualified electrical engineers...

Page 7: ...programming parameters Disconnect the drive from the mains whenever personal safety considerations make it necessary to avoid unintended motor start Check that the drive motor and any driven equipmen...

Page 8: ...he drive or performing any work on the cables WARNING BEFORE INSTALLATION REPAIR The operator or electrical installer is responsible for compliance with all applicable national and local safety regula...

Page 9: ...me 7 Connect power to the drive 8 Set up the input output functions in the corresponding parameters e30be183 11 1 2 5 4 3 1 LCP 3 Slot B 5 LCP frame 2 Terminal cover 4 Option Illustration 1 Installati...

Page 10: ...it the LCP in the cradle 1 2 3 4 e30be184 11 Illustration 2 Installation in Enclosure Sizes A5 B1 B2 B4 C D E and F 3 4 Electrical Installation 3 4 1 Specifications The VLT Programmable I O MCB 115 ha...

Page 11: ...Block Diagram 3 4 1 1 Programmable Inputs The analog inputs can be used for reference or process feedback for PID controllers They can work as Analog voltage inputs Analog current inputs Analog temper...

Page 12: ...impedance low as every 3 85 in cables gives a misreading of 1 Kelvin 3 4 1 2 Programmable Outputs The 3 programmable outputs can work as analog voltage outputs analog current outputs digital outputs...

Page 13: ...49 9 10 and X49 11 12 e30bt125 12 IN1 1 GND 2 IN2 3 GND 4 IN3 5 GND 6 OUT1 7 GND 8 OUT2 9 GND 10 OUT3 11 GND 12 MCB 115 OPTION B Programmable I O 130B1266 X49 SW ver xx xx Illustration 4 Terminal X49...

Page 14: ...of the information is not relevant Bolded text indicates highlighting and section headings Italicized text indicates the following Cross reference Link Footnote Parameter name Parameter option Parame...

Page 15: ...Installation Guide VLT Programmable I O MCB 115 AN295938195323en 000101 130R0655 15 Danfoss A S 2020 01...

Page 16: ...der provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies D...

Reviews: