6.3 Parameter List
Pa
r. No.
#
Para
mete
r description
Defa
ult value
4-
se
t-
up
FC
30
2
onl
y
Cha
nge duri
ng op-
erat
ion
Co
nver-
sio
n index
Type
8-0*
Gen
er
al Set
ti
n
g
s
8-
01
Contro
l Site
[0
] Digi
ta
l an
d ct
rl.
w
or
d
Al
l set-
ups
TR
U
E
-
Ui
nt
8
8-
02
Contro
l Word
Sou
rce
nu
ll
Al
l set-ups
TR
UE
-
Ui
nt8
8-
03
Co
ntrol
Wo
rd
Time
ou
t Ti
me
1.0
s
1
set-
up
TRU
E
-1
Ui
nt32
8-
04
Contro
l Word
Ti
me
out Function
nu
ll
1 set-
up
TR
UE
-
Ui
nt8
8-05
En
d-o
f-
Ti
m
eo
ut
Fu
ncti
on
[1
]
Resume
set
-up
1 se
t-u
p
TR
UE
-
U
in
t8
8-
06
Rese
t Co
ntrol W
ord
Tim
eout
[0
]
Do
not rese
t
Al
l set-ups
TR
UE
-
Ui
nt8
8-
07
Dia
gnosis Trigger
[0] Di
sab
le
2 s
et
-u
ps
TR
UE
-
Ui
nt8
8-1*
Ctr
l.
Wo
rd
S
et
ti
n
g
s
8-
10
Contro
l Word
Pr
ofil
e
[0
] FC
pro
fil
e
Al
l set-
ups
TR
U
E
-
Ui
nt
8
8-
13
Conf
ig
ura
ble S
tatu
s Wo
rd STW
[1
] P
ro
fil
e
de
faul
t
Al
l set-ups
TR
UE
-
Ui
nt8
8-
14
Conf
ig
ura
ble
Co
ntrol Word C
TW
[1
] P
ro
fil
e
de
faul
t
Al
l set-ups
TR
UE
-
Ui
nt8
8-3*
FC Por
t S
et
ti
n
gs
8-
30
Prot
ocol
[0]
FC
1 set-
up
TRU
E
-
U
in
t8
8-
31
Addre
ss
1 N/A
1 set-
up
TR
UE
0
Ui
nt8
8-
32
FC P
ort Baud
R
ate
nu
ll
1 set-
up
TRU
E
-
U
in
t8
8-
33
Parity /
St
op Bi
ts
[0] Eve
n
Pa
rity, 1 Stop
Bi
t
1 set-
up
TR
UE
-
Ui
nt8
8-
35
Mi
nim
um
Re
sp
onse
Del
ay
10
ms
Al
l se
t-up
s
TRU
E
-3
U
in
t16
8-
36
Max R
espo
nse
Delay
SR
1 set-
up
TR
UE
-3
Ui
nt16
8-
37
Max I
nter-Char
Delay
SR
1 set-
up
TR
UE
-5
Ui
nt16
8-4*
F
C
MC protocol set
8-
40
Te
le
gr
am se
le
ctio
n
[1
] St
anda
rd
tel
egra
m
1
2 s
et
-u
ps
TR
UE
-
Ui
nt8
8-5*
Dig
it
al/
Bus
8-
50
Coast
ing Se
lect
[3] Log
ic
O
R
Al
l set-
ups
TR
U
E
-
Ui
nt
8
8-
51
Q
ui
ck
St
op
Se
le
ct
[3] Log
ic
O
R
Al
l set-ups
TR
UE
-
Ui
nt8
8-
52
DC Brake
S
el
ect
[3] Log
ic
O
R
Al
l se
t-up
s
TRU
E
-
Ui
nt
8
8-
53
Sta
rt Se
le
ct
[3] Log
ic
O
R
Al
l set-ups
TR
UE
-
Ui
nt8
8-
54
Rev
ersin
g Sel
ect
[3
]
Lo
gic OR
All
set-
ups
TR
U
E
-
U
int
8
8-
55
Set
-up S
elect
[3] Log
ic
O
R
Al
l set-ups
TR
UE
-
Ui
nt8
8-
56
Pr
es
et
Re
fe
re
nc
e S
ele
ct
[3] Log
ic
O
R
Al
l set-ups
TR
UE
-
Ui
nt8
8-8*
FC P
o
rt
D
iagn
o
sti
cs
8-
80
Bus Messa
ge
Coun
t
0 N/A
Al
l set-
ups
TR
U
E
0
Ui
nt32
8-
81
Bus Error Co
unt
0 N/A
Al
l set-ups
TR
UE
0
Ui
nt32
8-
82
Sl
ave
Me
ssag
es Rc
vd
0
N/A
Al
l se
t-up
s
TRU
E
0
Ui
nt32
8-
83
Sl
av
e Err
or
Count
0 N/A
Al
l set-ups
TR
UE
0
Ui
nt32
8-9*
Bu
s
Jog
8-
90
Bus Jo
g 1
Sp
ee
d
100 R
PM
Al
l set-ups
TR
UE
67
Ui
nt16
8-
91
Bus Jo
g 2
Sp
ee
d
200 R
PM
Al
l se
t-up
s
TRU
E
67
U
in
t16
6 Parameters
MCA 121 EtherNet/IP
42
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark
6
Summary of Contents for VLT MCA 121 EtherNet/IP
Page 14: ...4 How to Configure MCA 121 EtherNet IP 14 MG 90 J2 02 VLT is a registered Danfoss trademark 4...
Page 20: ...5 How to Control MCA 121 EtherNet IP 20 MG 90 J2 02 VLT is a registered Danfoss trademark 5...
Page 50: ...8 Appendix MCA 121 EtherNet IP 50 MG 90 J2 02 VLT is a registered Danfoss trademark 8...