background image

1.5  Disposal

Do not dispose of equipment containing
electrical components together with
domestic waste.
Collect it separately in accordance with
local and currently valid legislation.

1.6  Symbols, Abbreviations, and

Conventions

Abbreviation

Definition

CAN

Controller area network

CiA

CAN in automation

COB

Communication object

COB-ID

Communication object identifier

CTW

Control word

EDS

Electronic data sheet

EMC

Electromagnetic compatibility

EMCY

Emergency message

I/O

Input/output

LCP

Local control panel

LED

Light emitting diode

LSB

Least significant bit

MAV

Main actual value (actual output)

MRV

Main reference value

MSB

Most significant bit

NMT

Network management

N/A

Not applicable

OD

Object directory

PCD

Process data

PDO

Process data object

PLC

Programmable logic controller

PNU

Parameter number

RPDO

Receive process data object

RPM

Revolutions per minute; unit for the speed of a
revolving motor

RTR

Remote transmission request frame

RX

Receive data

STW

Status word

SDO

Service data object

SYNC

Object for synchronisation of process data

TPDO

Transmit process data object

TX

Transmit data

Table 1.1 Symbols and Abbreviations

Conventions

Numbered lists indicate procedures.
Bullet lists indicate other information and descriptions of
illustrations.
Italicised text indicates:

Cross-reference.

Link.

Parameter name.

Footnote.

Parameter group.

Parameter option.

Alarms/warnings.

Introduction

Installation Guide

MG33J402

Danfoss A/S © 05/2015 All rights reserved.

3

1

1

Summary of Contents for VLT AutomationDrive FC 301

Page 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide VLT CANopen MCA 105 VLT AutomationDrive FC 301 302 vlt drives danfoss com...

Page 2: ......

Page 3: ...ion 6 3 1 Safety Instructions 6 3 2 EMC compliant Installation 6 3 3 Grounding 6 3 4 Cable Routing 6 3 5 Mounting 7 3 6 Setting Address Switches 8 3 7 Electrical Installation 8 3 8 Reassembling Cover...

Page 4: ...ng Guide provides information about configuring the system controlling the frequency converter parameter access programming troubleshooting as well as some typical application examples Supplementary p...

Page 5: ...nificant bit NMT Network management N A Not applicable OD Object directory PCD Process data PDO Process data object PLC Programmable logic controller PNU Parameter number RPDO Receive process data obj...

Page 6: ...sharing the motor may start at any time Unintended start during programming service or repair work can result in death serious injury or property damage The motor can start with an external switch a...

Page 7: ...ectrical work conforms to national and local electrical codes Follow the procedures in this manual CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious...

Page 8: ...ns as short as possible Establish electrical contact between the cable screen and the frequency converter enclosure by using metal cable glands or by using the clamps provided on the equipment Use hig...

Page 9: ...on 3 3 or with the connector facing down for bottom cable entry see Illustration 3 4 If an MCB option is installed only top cable entry is possible 5 Remove the knock out plate from the new LCP cradle...

Page 10: ...Resistance m m Cable cross section mm2 Termination resistor 500 100 60 0 34 0 6 120 250 250 40 0 5 0 6 125 500 50 1000 26 0 75 0 8 20 2500 10 5000 Table 3 3 Cable Specifications 3 7 2 Wiring Procedure...

Page 11: ...cable through cable glands 2 Mount the fieldbus connector on the fieldbus option CAN_L Drain CAN_H 3 Prepare the fieldbus cable by stripping a section of the cable insulation Keep the unshielded wire...

Page 12: ...ide the unit see Illustration 3 9 130BC527 10 Illustration 3 9 Wiring for Enclosure Sizes D E and F 3 8 Reassembling Cover 1 Mount the new front cover and the LCP 2 Attach the sticker with the correct...

Page 13: ...off state Table 4 1 LED Module Status MS State Red LED Description Stopped Single flash Device in stopped state Pre operational Triple flash Device in pre operational state Operational On Device in op...

Page 14: ...6 EMC interference 6 EMC compliant installation 6 Exploded view 7 G Grounding 6 H High voltage 4 I Intended use 2 Items supplied 2 L Leakage current 4 LED panel 11 LED status 11 Load sharing 4 M Moto...

Page 15: ...Index Installation Guide MG33J402 Danfoss A S 05 2015 All rights reserved 13...

Page 16: ...ucts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the resp...

Reviews: