Enclosure size F top entry kit
mains cables
The kits include everything required to install a
top entry section onto the mains side (left side)
of an F size enclosure.
Ordering number
F1/F2, 400 mm ....................................................176F1832
F1/F2, 600 mm ....................................................176F1833
F3/F4 with disconnect, 400 mm ............. 176F1834
F3/F4 with disconnect, 600 mm ..............176F1835
F3/F4 without disconnect, 400 mm ..... 176F1836
F3/F4 without disconnect, 600 mm ......176F1837
F8, F9, F10, F11, F12, F13 .................
Contact factory
Common motor terminal kits
The common motor terminal kits provide the
busbars and hardware required to connect the
motor terminals from the paralleled inverters to
a single terminal (per phase) to accommodate
the installation of the motor-side top entry kit.
This kit is equivalent to the common motor ter-
minal option of a drive. This kit is not required
to install the motor-side top entry kit if the
common motor terminal option was specified
when the drive was ordered.
This kit is also recommended to connect the
output of a drive to an output filter or output
contactor. The common motor terminals
eliminate the need for equal cable lengths
from each inverter to the common point of the
output filter (or motor).
Ordering number
F1/F2, 400 mm ....................................................176F1832
F1/F2, 600 mm ....................................................176F1833
Adapter plate
The adapter plate is used to replace an old
enclosure size D drive with the new enclosure
size D drive, using the same mounting.
Ordering number
D1h/D3h adapter plate to replace
D1/D3 drive ..........................................................176F3409
D2h/D4h adapter plate to replace
D2/D4 drive .......................................................... 176F3410
Back-channel duct kit
Back-channel duct kits are offered for con-
version of enclosure sizes D and E. They are
offered in two configurations – in-bottom/out-
top venting and top only venting. Available for
enclosure sizes D3h and D4h.
Ordering number top and bottom
D3h kit 1800 mm without pedestal .....176F3627
D4h kit 1800 mm without pedestal .....176F3628
D3h Kit 2000 mm with pedestal .............176F3629
D4h Kit 2000 mm with pedestal ............176F3630
NEMA 3R Rittal
and welded enclosures
The kits are designed to be used with the
IP00/IP20/Chassis drives to achieve an ingress
protection rating of NEMA 3R or NEMA 4. These
enclosures are intended for outdoor use to pro-
vide a degree of protection against inclement
weather.
Ordering number for
NEMA 3R (welded enclosures)
D3h back-channel cooling kit
(in back out back)............................................. 176F3521
D4h back-channel cooling kit
(in back out back)............................................. 176F3526
Ordering number for
NEMA 3R (Rittal enclosures)
D3h back-channel cooling kit
(in back out back).............................................176F3633
D4h Back-channel cooling kit
(in back out back).............................................176F3634
E4h (in back/out back) ...................................176F6611
E3h (in bottom/out back)
600 mm bottom plate ...................................176F6612
E3h (in bottom/out back)
800 mm bottom plate ...................................176F6613
E4h (in bottom/out back)
800 mm bottom plate .................................. 176F6614
E3h (in back/out top) ......................................176F6615
E4h (in back/out top) ..................................... 176F6616
Pedestal kit with in-back/
out-back cooling
See additional documents 177R0508 and
177R0509.
Ordering number
D1h 400 mm kit ................................................. 176F3532
D2h 400 mm kit ................................................. 176F3533
Pedestal kit
The pedestal kit is a 400 mm high pedestal for
enclosure sizes D1h and D2h, and 200 mm high
for enclosure sizes D5h and D6h, that allows
the drives to be floor mounted. The front of the
pedestal has openings for input air to cool the
power components.
Ordering number
D1h 400 mm kit ................................................. 176F3631
D2h 400 mm kit .................................................176F3632
D5h/D6h 200 mm kit .....................................176F3452
D7h/D8h 200 mm kit ..................................... 176F3539
Input-plate option kit
Input-plate option kits are available for enclo-
sure sizes D and E. The kits can be ordered to
add fuses, disconnect/fuses, RFI, RFI/fuses and
RFI/disconnect/fuses. Please consult the factory
for kit ordering numbers.
Top entry of fieldbus cables
The top entry kit provides the ability to install
fieldbus cables through the top of the drive.
The kit is IP20 when installed. If an increased
rating is desired, a different mating connector
can be used.
Ordering number
D1h-D8h .................................................................176F3594
LCP Remote Mounting Kit
The LCP Remote Mounting Kit offers an easy-
to-install, IP54 design which you can mount
on panels and walls of 1-90 mm thickness. The
front cover blocks the sunlight for convenient
programming. The closed cover is lockable
to prevent tampering, while keeping the On/
Warning/Alarm LEDs visible. It is compatible
with all VLT® Local Control Panel options.
Ordering number for IP20 enclosure
3 m cable length .............................................. 134B5223
5 m cable length ...............................................134B5224
10 m cable length ............................................ 134B5225
Ground bar kit
More grounding points for E1h and E2h drives.
The kit includes a pair of ground bars for instal-
lation inside the enclosure.
Ordering number
E1h/E2h ...................................................................176F6609
Back-channel cooling kits
for non-Rittal enclosures
The kits are designed to be used with the
IP20/Chassis drives in non-Rittal enclosures for
in-back/out-back cooling. Kits do not include
plates for mounting in the enclosures.
Ordering number
D3h .............................................................................176F3519
D4h ............................................................................ 176F3524
Ordering number for corrosion resistant
D3h ............................................................................176F3520
D4h ............................................................................176F3525
Back-channel cooling kit
(in-bottom/out-back)
Kit for directing the back-channel air flow in the
bottom of the drive and out the back.
Ordering number
D1h/D3h .................................................................176F3522
D2h/D4h .................................................................176F3527
Ordering number corrosion resistant
D1h/D3h .................................................................176F3523
D2h/D4h ................................................................ 176F3528
Back-channel cooling kit
(in-back/out-back)
These kits are designed to be used for
redirecting the back-channel air flow. Factory
back-channel cooling directs air in the bottom
of the drive and out the top. The kit allows the
air to be directed in and out the back of the
drive.
Ordering number for
in-back/out-back cooling kit
D1h.............................................................................176F3648
D2h ............................................................................176F3649
D3h ............................................................................176F3625
D4h ............................................................................176F3626
D5h/D6h ................................................................176F3530
D7h/D8h .................................................................176F3531
Ordering number for corrosion resistant
D1h.............................................................................176F3656
D2h ............................................................................176F3657
D3h ............................................................................176F3654
D4h ............................................................................176F3655
Ordering number for
VLT® Low Harmonic Drives
D1n.............................................................................176F6482
D2n ............................................................................176F6481
E9 ...............................................................................176F3538
F18 ..............................................................................176F3534
Ordering number for
VLT® Advanced Active Filter AAF 006
D14 ............................................................................. 176F3535
Telescopic
back-channel cooling kit
Back-channel cooling kits for IP20/Chassis
drives allow the heat sink air of the drive to be
directed out of the panel in which the drive is
installed. The new telescopic provides more
flexibility and easier installation to fit inside the
panel.
The kits are supplied in almost pre-assembled
condition, and include a gland plate that fits
standard Rittal enclosures.
Ordering numbers for E-frames:
E3h (in bottom/out top)
600 mm bottom plate ..................................176F6606
E3h (in bottom/out top)
800 mm bottom plate ..................................176F6607
E4h (in bottom/out top)
800 mm bottom plate ..................................176F6608
E3h (in back/out back) .................................. 176F6610
55