C A U T I O N
HOT SURFACES
The drive contains metal components that are still hot even after the drive has been powered off. Failure to observe the high
temperature symbol (yellow triangle) on the drive can result in serious burns.
Be aware that internal components, such as busbars, may be extremely hot even after the drive has been powered off.
Do not touch exterior areas that are marked by the high temperature symbol (yellow triangle). These areas are hot while the
drive is in use and immediately after being powered off.
2.5 Lifting the Drive
N O T I C E
LIFTING HEAVY LOAD
The weight of the drive is heavy and failure to follow local safety regulations for lifting heavy weights may cause death, personal
injury, or property damage.
Ensure that the lifting equipment is in proper working condition.
Check the weight of the drive and verify that the lifting equipment can safely lift the weight.
Always lift the drive using a lifting bar inserted into the lifting eyes. Maximum diameter for the lifting bar: 20 mm (0.8 in).
The angle from the top of the drive to the lifting cable: 60° or greater.
Test lift the unit approximately 610 mm (24 in) to verify the proper center of gravity lift point. Reposition the lifting point if
the unit is not level.
Table 2: Drive Weights and Dimensions
Enclosure size
Protection rating
Dimensions (HxWxD) [in]
Weight [lb]
A2
IP20/Chassis
10.6x3.6x8.7
10.8
A3
IP20/Chassis
10.6x5.2x8.7
14.6
A5
IP66 - Type 4X
16.6x9.6x7.9
31.5
B1
IP66 - Type 4X
18.9x9.6x10.3
51
B2
IP66 - Type 4X
25.6x9.6x10x3
60
B3
IP20/Chassis
15.8x6.5x9.8
26.5
B4
IP20/Chassis
20.5x9.1x9.6
52
C1
IP66 - Type 4X
26.8x12.2x12.3
99
C2
IP66 - Type 4X
30.4x14.6x13.2
143
C3
IP20/Chassis
21.7x12.2x13
77
C4
IP20/Chassis
26x14.6x13
110
D1h
Type 12
35.5x12.8x14.9
136.7
D2h
Type 12
43.6x12.8x14.9
275.6
D3h
IP20/Chassis
35.8x19.8x14.8
136.7
D4h
IP20/Chassis
44.2x14.8x14.8
238.1
AN354546796134en-000201 / 130R0954
6 | Danfoss A/S © 2021.05
Safety Instructions
VLT®AutomationDrive EZ FC 321
Installation Guide