5-10 Terminal 18 Digital Input
Option:
Function:
[1]
Reset
Resets filter after a TRIP/ALARM. Not all
alarms can be reset.
[6]
Stop inverse
Stop Inverted function. Generates a stop
function when the selected terminal goes
from logical level ‘1’ to ‘0’.
[8]
*
Start
(Default Digital input 18): Select start for a
start/stop command. Logic ‘1’ = start, logic
‘0’ = stop.
[9]
Latched Start
The filter starts, if a pulse is applied for
min. 2 ms. The filter stops when Stop
inverse is activated.
[23]
Set-up select
bit 0
Select Set-up select bit 0 or Select Set-up
select bit 1 to select one of the four set-
ups. Set
to Multi Set-up.
[24]
Set-up select
bit 1
(Default Digital input 32): Same as Set-up
select bit 0 [23].
[32]
Master cmd
pulse in
Time based pulse input measures the
duration between flanks. This gives a
higher resolution at lower frequencies, but
is not as precise at higher frequencies. This
principle has a cut-off frequency which
makes it unsuited for encoders with very
low resolutions (e.g. 30 ppr) at low speeds.
[99]
Follower AF
#1 Run
Feedback
Do not program this setting. It is done
automatically for paralleling. See
300-40 Master Follower Selection
and
for more infomation
about paralleling.
[100] Follower AF
#2 Run
Feedback
Do not program this setting. It is done
automatically for paralleling. See
300-40 Master Follower Selection
and
for more infomation
about paralleling.
[101] Sleep
The filter goes into sleep mode at light
duty to save energy.
5-11 Terminal 19 Digital Input
Option:
Function:
[0]
*
No Operation Functions are described under 5-1*
Digital
Inputs
5-12 Terminal 27 Digital Input
Option:
Function:
[0]
*
No Operation Functions are described under 5-1*
Digital
Inputs
5-13 Terminal 29 Digital Input
Option:
Function:
[0]
*
No Operation Functions are described under 5-1*
Digital
Inputs
5-14 Terminal 32 Digital Input
Option:
Function:
[90]
*
AC Contactor Functions are described under 5-1*
Digital
Inputs
5-15 Terminal 33 Digital Input
Option:
Function:
[91]
*
DC Contactor Functions are described under 5-1*
Digital
Inputs
5-16 Terminal X30/2 Digital Input
Option:
Function:
[0]
*
No operation Functions are described under 5-1*
Digital
Inputs
5-17 Terminal X30/3 Digital Input
Option:
Function:
[0]
*
No operation Functions are described under 5-1*
Digital
Inputs
5-18 Terminal X30/4 Digital Input
Option:
Function:
[0]
*
No operation Functions are described under 5-1*
Digital
Inputs