
26
MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mains supply 3 x 440/460/500 V
Technical data
Acc. to international VDE and UL/CSA requirements
VLT type
3002
3003
3004
3006
3008
3011
3016 3022 3032 3042
3052
Constant torque (CT):
Output current
I
VLT,N
[A]
2.6
3.4
4.8
8.2
11.1
14.5
21.7 27.9 41.4 54.0
65.0
I
VLT,MAX
[A] (60s)
3.4
5.5
7.7
13.1
17.6
23.2
34.7 44.6 67.2 86.4 104.0
Output
S
VLT,N
[kVA]
2.3
2.9
4.1
7.1
9.6
12.6
18.8 24.2 36.0 46.8
56.3
S
VLT,MAX
[kVA] (60s)
2.9
4.7
6.7
11.3
15.2
20.1
30.1 38.6 58.2
7.8
90.1
Typical shaft output
P
VLT,N
[kW]
1.1
1.5
2.2
4.0
5.5
7.5
11.0 15.0 22.0 30.0
37.0
Quadratic torque (VT):
Output current
I
VLT,N
[A]
2.6
3.4
4.8
8.2
11.1
21.7
27.9 41.4 54.0 65.0
78.0
Output
S
VLT,N
[kVA]
1.6
2.9
4.1
7.1
9.6
18.8
24.2 35.9 46.8 56.3
67.5
Typical shaft output
P
VLT,N
[kW]
1.1
1.5
2.2
4.0
5.5
11.0
15.0 22.0 30.0 37.0
45.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0
16.0 16.0 35.0 35.0
50.0
Max. motor cable length
[m]
300, with screened cables: 150 m (3011-3052 in VT: 150 m and 40 m)
Output voltage
U
M
[%]
0-100, of mains voltage
Output frequency
f
M
[Hz]
0-120 eller 0-500, programmable
Rated motor voltage
U
M,N
[V]
440/460/500
Rated motor frequency
f
M,N
[Hz]
50/60/87/100
Thermal protection during operation
Integrated thermal motor protection (electronic); thermistor to DIN 44081
Switching on output
Unlimited (frequent switching on output may result in fault message)
Ramp times
[s]
0.1 – 3600
VLT
type
3002
3003
3004
3006
3008
3011
3016 3022 3032 3042
3052
Max.
const. load. [A]
2.6
3.4
4.8
8.2
11.1
12.6
20.1 26.8 37.3 50.2
61.3
input current
quadratic load [A]
2.6
3.4
4.8
8.2
11.1
19.6
26.0 34.8 48.6 60.3
72.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0
16.0 16.0 35.0 35.0
50.0
Max. pre-fuses
[A]
16.0
16.0
16.0
25.0
25.0
30.0
40.0 50.0 60.0 100.0
1)
125.0
1)
Supply voltage (VDE 0160)
[V]
3 x 440/460/500 ±10% (VDE 0160)
Supply frequency
[Hz]
50/60
Power factor / cos.
ϕ
1
0.9/1.0
Efficiency
0.96 at 100% load
Switching on input
times/min.
2
VLT type
3002
3003
3004
3006
3008
3011
3016 3022 3032 3042
3052
Weight (kg)
IP 00
7.4
7.4
7.4
12
14
-
-
-
-
-
-
IP 20
-
-
-
-
-
25
26
31
49
54
54
IP 21
8.0
8.0
8.0
13
15
-
-
-
-
-
-
IP 54
11
11
11
14
15
34
37
48
63
69
69
Power loss at max. load
CT [W]
60
100
130
160
200
174
287
580 958 1125
1467
VT [W]
60
100
130
160
200
281
369
880 1133 1440
1888
Enclosure
VLT type 3002-08: IP 00 / IP 21 / IP 54 VLT type 3011-52: IP 20 /IP54
VLT type 3042-52: IP 20 / IP 54
Vibration test
[g]
0.7
Relative humidity
[%]
VDE 0160 5.2.1.2.
[°C]
-10
→
+40
-10
→
+45/40(CT/VT)
Ambient temperature
at full load
2)
at full load
2)
(to VDE 0160)
[°C]
-25
→
+65/70
-25
→
+65/70
in storage/transport
in storage/transport
Frequency converter protection
Protection against earthing and short-circuiting
EMC standards
Emission
EN 55011, EN 55014
(See section “EMC test results”)
Immunity
EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
1) Semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the specifications.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com