background image

3

BROWN

A

B

C

1

2

3

4

5

6

BROWN

BLUE

A

B

C

1

2

3

4

5

6

N

HPA2

Switched Live to

boiler & pump

control circuit

MAINS

Fused 3 Amp.

TP75

A

B

C

1

2

3

4

5

6

N

ZONE CONTROL

BOILER

&

PUMP

N

MAINS

Fused 3 Amp.

N

TP75

A

B

C

1

2

3

4

5

6

DIRECT BURNER CONTROL

COMBI BOILER CONTROL

MAINS

Fused 3 Amp.

OUTPUT     INPUT

L    N

Combi Boiler
Terminals

A

B

C

1

2

3

4

5

6

TP75

HEATING SYSTEM CONTROL (HEATSHARE)

N

L

1

2

3

4

BOILER

&

PUMP

N

MAINS

Fused 3 Amp.

N

TS15 or TS75  (DHW)

TP75 (A)

MAINS

Fused 3 Amp.

N

ORANGE

BROWN/WHITE

GREY

BLUE

HSA3

HEATING SYSTEM CONTROL (HEATPLAN)

MAINS
Fused 3
Amp.

N

L

1

2

3

4

TP75 (A)

TS15 or TS75  (DHW)

N

GREY

N

MAINS

Fused 3 Amp.

HPA2

DHW

HPA2

HTG

BLUE

ORANGE

N

ORANGE

GREY

3

2

1

L

ATC

ATC

3

2

1

L

BOILER

&

PUMP

N

L

Remote Sensor

connections,

if used.

Remote Sensor

connections, if used.

Remote Sensor

connections, if used.

Remote Sensor

connections,

if used.

Remote Sensor

connections,

if used.

TP75

A

B

C

1

2

3

4

5

6

N

ZONE CONTROL with ABN-NC Actuator

Remote Sensor

connections,

if used.

N

Switched Live
Output

Live Input

2 port Valve

A B C 1 2 3 4 5 6

Live

Input

On  Off

Heating

ELECTRONICS

INTERNAL WIRING

TYPICAL CONTROL

CIRCUITS

The use of Danfoss Randall Control

Packs with WB12 wiring centre is

recommended.

Cut out terminal to terminal wiring

details for HEATSHARE (HSP) and

HEATPLAN (HPP) PACKS above and

use with the WB12.

Insert for cover of WB12
Wiring Centre.  Cut-out and
place over pillars in cover.

$

HEATSHARE 

SYSTEM

L    N

L    N

L    N

L    N

L    N

RTS

Remote

Telesw.

if Fitted

TS2

Remote

Sensor

if Fitted

TP75

Remote Devices

COM

On Off

A

B C

1

2

3

4

5

6

2

8

TS75 or TS15

Off

On

N L

1

2

3 4

6

9

10

11

11

12

10

5

ATC

COM

N

/

C

N

/

O

CALL

SAT

1

2

3

1

2

3

4

5

6

7

8

9

10

11

12

N

L

N

L

MAINS

FUSED

3A

1

2 3

WIRING CONNECTIONS FOR

TP75 WITH A TS75 HSP or TS15 HSP

Heatshare Control Pack

4

5

6

7

PERM. 

L

SW. 

L

N

BOILER

PUMP

IF 

REQUIRED

BLUE

BRN/WH.

GREY

ORANGE

1

8

10 12

HEATSHARE

ACTUATOR

IF BOILER DOES NOT HAVE PUMP TERMINALS, CONNECT PUMP

TO 7 (L), 6 (N) & 5   (     ) ON WB12.

TP75B  connections  A  B

TP75AB  connections  C  1