11
U
ser Instruc
tions
GB
Option 1 - Enable or disable A/B programming (Option 41 set to 5+2)
This enables or disables the A/B programming option. Press
+
until Option 1 is displayed, use
Λ
and
V
to select required
setting.
Setting 0
Disabled, unit operates as 5/2 or 24 hour product depending on
installer settings (factory setting)
Setting 1
Enabled: activates A/B programming
Option 3 - Calendar clock rules
This establishes the rules that the automatic calendar clock
follows to calculate changes between summer and winter
time. Press
+
until Option 3 is displayed, use
Λ
and
V
to select
required setting.
Setting 0
Disabled.
Setting 1
Manual: user must change using
+
to advance and
-
to retard
displayed time.
Setting 2
European rules. (Factory Setting)
Setting 3
USA rules (2007 onwards)
Setting 4
USA rules (pre-2007)
Option 4 - Time zone off set
This feature allows the time zone to be established and
corrects time display. Press
+
until Option 4 is displayed, use
Λ
and
V
to select required setting
Setting 0
UK models: this feature should be left at the factory setting of 0.
Setting 1
Central European time models: this feature should be left at the
factory setting of +1:00.
-12 Hours +14 Hours
Rest of World: use
Λ
and
V
keys to select off set from Universal time (GMT) for the
location in which the thermostat is being installed.
Option 10 - Frost/ thermostat mode setting
This feature allows the default frost/thermostat mode
temperature to be set. Press
+
until Option 10 is displayed, use
Λ
and
V
to select required setting.
5-40°C -
Factory setting is 8°C, but can be changed to any value between 5 -40°C.
Summary of Contents for TP5001 series
Page 43: ...43 5 2 24 A B 2 4 6 53 TP5001 UA...
Page 45: ...45 54 PROG 3 V V V PROG 10 UA...
Page 46: ...46 PROG RUN 44 5 2 47 47 A B 48 PROG RUN PROG RUN 2 UA...
Page 48: ...48 c V d PROG 2 e b c d AB 5 2 PROG V 3 1 V 1 0 PROG 5 RUN PROG 1 2 3 4 5 V 2 7 UA...
Page 49: ...49 a PROG 1 b 10 c V d PROG 2 e b c d a PROG 1 b 10 c V d PROG 2 e b c d RUN PROG UA...
Page 50: ...50 V 12 24 12 24 C F C F V UA...
Page 51: ...51 a 5 30 C b V 8 C 10 55 c d V e V UA...
Page 52: ...52 10 55 V V 11 55 OSC 12 13 56 15 RESET UA...
Page 53: ...53 V PROG 3 V UA...
Page 55: ...55 11 11 V 0 1 OSC 120 0 12 2 OSC 10 10 V 5 40 C 8 C 5 40 C UA...
Page 57: ...57 15 UA...
Page 58: ...58 RESET RESET PROG UA...
Page 88: ...88 Kullan c Talimatlar TR...