Assembly / Installing the system:

DHS-SMTL / PL

Legend:

1)    Domestic water (cold) 

2)    Domestic water (hot) 

3)    Circulation (connection optional) 

4)    Heating, supply 

5)    Heatnig, return 

37)  Connection for instantaneous 

    water heater (HEL)

DTA   Domestic buffer tank 

HEL   instantaneous water heater 

  (heat 

exchanger) 

LPU  Storage tank charging pump 

D    Balancing and flow control valve 

SFV  Safety valve 

FI    Thermometer (charge) 

21   Thermometer (tank) 

G    Shut-off ball valve 

M    Upper connection piece with 

    shut-off ball valve (gunmetal) 

N    Lower connection piece (gunmetal) 

P    Heat exchanger bracket 

Q    Connection part (brass) 

R    Connection pipe (stainless steel) 

Z1   Safety temperature monitor muff 

    (see tank data sheet) 

Z4   Connection for sensor charge 

22   Sensor muff 

23   Drain connection muff 

25   Cleaning and inspection opening 

29   Ventilation sleeve / lifting eye 

  connection

Note: 

Unused connections/muffs must be closed 

(plugs/caps not included)

Quick Guide

 ThermoDual®-GS 

VQMPC102_ThermoDual-GS_181220.indd   1

20.12.2018   08:55:37

Summary of Contents for ThermoDual-GS

Page 1: ...ing pump D Balancing and flow control valve SFV Safety valve FI Thermometer charge 21 Thermometer tank G Shut off ball valve M Upper connection piece with shut off ball valve gunmetal N Lower connection piece gunmetal P Heat exchanger bracket Q Connection part brass R Connection pipe stainless steel Z1 Safety temperature monitor muff see tank data sheet Z4 Connection for sensor charge 22 Sensor mu...

Page 2: ...www danfoss com Page 11 pOlsKI Skręcane płytowe wymienniki ciepła XG www danfoss pl Strona 12 РУССКИЙ Инструкции XG www danfoss ru Стр 13 ČEsKY Tepelné výměníky rozebíratelné XG www danfoss com Strana 15 DAnsK Boltede varmevekslere XG www danfoss dk Side 16 rOMÂnĂ Schimbătoare de căldură cu garnitură XG www incalzire danfoss com Pagina 17 ITAlIAnO Scambiatore di calore guarnizionato XG www danfoss...

Page 3: ...n the heat exchanger and the domestic water storage tank accordingly in their position Make sure both units are positioned horizontally at the same height this is the only way the supplied components and tubes fit perfectly Connect all parts according to the drawing using the respective screwed connections and do not forget to insert the loose enclosed gaskets beforehand When assembling adjust the...

Page 4: ...ightness 10 max 35 Nm See also chapter 5 1 in the installation and operating instructions It is best to manually tighten all screw connections and correct when filling the system only until the respective connection no longer leaks It is best to tighten all screw connections only by hand and correct when filling the system only until the respective connection no longer leaks Finally mount the heat...

Reviews: