background image

1

09/2017 

© Danfoss 

VU.IG.B9.02

www.heating.danfoss.com

Installation guide

SonoSelect and SonoSafe

Energy Meters

Summary of Contents for SonoSelect

Page 1: ...1 09 2017 Danfoss VU IG B9 02 www heating danfoss com Installation guide SonoSelect and SonoSafe Energy Meters...

Page 2: ...eters 2019 03 VU IG B9 02 Installation guide SonoSelect and SonoSafe Product category Energy Meters Type designation s SonoSelect 10 and SonoSafe 10 Note To ensure latest version of declaration please...

Page 3: ...tallation 5 2 4 Mounting orientation calculator 5 2 5 Mounting of O ring and temperature sensor 6 2 6 Bifunctional meters 7 2 7 Communication modules 7 2 8 Installation of module cable 11 2 9 Battery...

Page 4: ...a wall mounting kit is delivered with the product For mains supply meters a M12 gland is delivered with the product 2 Installation 2 1 Preparation SonoSelect incorporates a tamper monitoring function...

Page 5: ...Heat meters and bifunctional meters have red temp sensor in supply pipe and all cooling meters have blue temp sensor in supply pipe 2 3 Flow sensor installation Pipe position No limitations but avoid...

Page 6: ...ounting pin available as accessory 1 Mount O ring on pin 2 Insert pin with O ring 3 Position O ring 4 Remove pin 5 Moist and insert sensor probe Tighten at torque 12 2 Nm To ensure accuracy and a tigh...

Page 7: ...in legal backup every 10 minute Power Lithium Thionyl Chloride battery half of AA size or mains power supply 230V In case of power cuts on mains power the module has no power back up 2 pulse in output...

Page 8: ...in Walk by 2 min Mains power 16 seconds Telegram Standard telegram Battery life time 16 1 year with pulse inputs off Addressing Serial number sssssvvNNyyWW yWWsssss Secondary address See section with...

Page 9: ...in meter if 1 Module battery is empty 2 When no of delayed pulses exceeds 5000 incorrect scaling Default setting Can be changed via SonoApp Data telegram Wired M bus Standard telegram 16 seconds if ma...

Page 10: ...utput 1 white 17 Pulse output 2 brown 18 Pulse output 2 white 19 Name Dimensions Cable specification Pulse input cables 22AWG 10m Pulse output cables 22AWG 25m To ensure IP protection class connecting...

Page 11: ...to enclosure Click 4 Insert module following guide on PCBA cover Insert cable through hole connect cable and fix to screw terminals matching colour and terminal numbers Fix cable s to cable relief Out...

Page 12: ...nnectors on PCB using a small flat head screwdriver 5 Connect new battery to PCB 6 Fit battery in enclosure Click 7 Close enclosure making sure that no cables interfere with rubber sealing or other in...

Page 13: ...not connect the cable to 230V before installing it in energy meter 2 Break installation seal on both sides and open enclosure 3 Screw on the cable gland 4 Remove protective cap from screw terminals 5...

Page 14: ...on module Left white plug for meter to have back up for power cut Right black for module 9 Close enclosure making sure that no cables interfere with rubber sealing or other internal parts Power up the...

Page 15: ...or SonoSelect Run installation check using Bluetooth dongle 014U1963 and SonoApp service tool 3 2 Supply return configuration Only available for SonoSelect Use Bluetooth dongle 014U1963 and SonoApp se...

Page 16: ...tton Tarif function can be added via SonoApp 4 1 Menu structure Hours Alarm Heat Cool Heat Energy Heat Volume Cooling Energy Cooling Volume LOOP 1 Supply temp Display test All on Power Flow LOOP 2 Acc...

Page 17: ...urn temperature Wireless communication Temperature difference Pulse Decimal emphasizer Units field 4 3 Alarms E01 System error E10 Transducer error E02 PCB error E11 Outside measured range E03 Battery...

Page 18: ...Module PCB 12 Bottom part PC 13 Temperature sensor 6 Disposal Item Material Disposal Battery AA cell Lithium thionyl chloride 620 mg Lithium Approved deposit for lithium batteries PCBA with display a...

Page 19: ...VU IG B9 02 Danfoss Energy Meters 2019 03 19 Installation guide SonoSelect and SonoSafe...

Page 20: ...e This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this materi...