Series 90 Master Model Code
R
Size
M
P
J
G
N F
L
H
T
W
Y
Z
K
S90
Size
042
055
075
100
130
180
250
042
42 cc [2.56 in
3
] max. displacement per revolution
O
055
55 cc [3.36 in
3
] max. displacement per revolution
O
075
75 cc [4.58 in
3
] max. displacement per revolution
O
100
100 cc [6.10 in
3
] max. displacement per revolution
O
130
130 cc [7.93 in
3
] max. displacement per revolution
O
180
180 cc [10.98 in
3
] max. displacement per revolution
O
250
250 cc [15.26 in
3
] max. displacement per revolution
O
R
Type and Rotation
042
055
075
100
130
180
250
R
Right Hand [CW]
O
O
O
O
O
O
O
L
Left Hand [CCW]
O
O
O
O
O
O
O
M
Controls
042
055
075
100
130
180
250
CA
cover plate without feedback link, no control
O
O
O
O
O
O
DC
3 positon F-N-R solenoid control (12 V , DC) DIN- connector
O
O
O
O
O
O
DD
3 positon F-N-R solenoid control (24 V , DC) DIN- connector
O
O
O
O
O
O
O
HF
HDC 2, std. porting, 3,0 - 11 BAR (44 - 160 PSI)
O
O
O
O
O
O
O
KA
EDC, MS connector, std. porting, dual coil (14 - 85 mA)
O
O
O
O
O
O
O
KN
EDC, MS connector, std. porting, 643 Ohm single coil (4 - 20 mA)
O
O
O
O
O
O
O
KT
EDC, Deutsch connector, std porting, dual coil ( 14 - 85 mA)
O
O
O
O
O
O
KP
EDC, Weatherpack connector, std. porting, dual coil (14 - 85mA)
O
O
O
O
O
O
O
MA
MDC
O
O
O
O
O
O
O
MB
MDC with neutral start switch
O
O
O
O
O
O
O
FA
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
O
O
O
FB
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
O
O
O
FC
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) (NFPE control)
O
O
O
FD
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) (NFPE control)
O
O
O
FG
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
O
O
O
O
FH
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
O
O
O
O
FK
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
O
FL
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 25 bar) (NFPE control)
O
FM
electrohydraulic displacement control without feedback link, 12V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
O
FN
electrohydraulic displacement control without feedback link, 24V with AMP Minitimer
connector, proportional solenoid with pressure reducing valve ( 32 bar) fast response
(NFPE control)
O
Series 90 Master Model
Code
O
O
Technical Information
Series 90 Axial Piston Pumps
Master Model Code
520L0603 • Rev 0804 • March 2016
21