The device can be directly bolted into spaced drill holes, see
on page 22. The
device can be mounted in any position,
The devices have integrated antennas and must be installed properly to the machine to avoid bolt
interference and to ensure the recommended line of sight to the sky.
Excessively long bolts, or metallic elements in general, may interfere with radio signal.
Care must be taken to insure that the module connector is positioned so that moisture drains away from
the connector. Provide a drip loop in the harness. Provide strain relief for mating connector wires.
C
Caution
Module damage may occur.
Use caution when installing modules. It's possible to damage the module if excessive pressure is applied
during the installation of harness strain relief.
Fasteners
Recommended outer diameter (OD)
Recommended torque
6.0 mm (0.25 in)
2.26 N•m (20 in•lbs)
Inside mount
Simple mounting option
Top Mount
The connector is facing inward through mounting surface, which allows for mounting on top of the
machine for best antenna exposure.
Recommended mounting option
Raises to IP69k rating, when top mounted and connector is plugged in (or suitably capped for
protection).
Technical Information
PLUS+1 Connect CS100 IoT Gateway — Professional Install Only
Mounting
©
Danfoss | October 2020
BC299456869228en-000101 | 23