Resistance input
Description
Unit
Minimum
Typical
Maximum
Comment
Range
Ω
5.2
—
10000
In steps of 1 Ω
Measurement error
%
—
—
6.4
100Ω
—
—
1.9
1kΩ
—
—
4.9
10kΩ
Input impedance
kΩ
1.32
1.32
1.33
Input impedance to 5V
Outputs
Digital output
Description
Unit Minimum Typical Maximum Comment
Output Voltage range V
0
-10.3
-22.3
@Vin=12v & 500ma
@Vin= 24V & 500ma
Current
mA 0
—
500
Each output pin capable of driving 500mA. No
current limiting; damage may be done if the load
pulls more than 500mA.
Technical Information
PLUS+1 Connect CS100 IoT Gateway — Professional Install Only
CS100 Technical Data
©
Danfoss | October 2020
BC299456869228en-000101 | 19