background image

Technical Information

PLUS+1® Connect

CS100 IoT Gateway

www.danfoss.com

Summary of Contents for PLUS+1 Connect CS100

Page 1: ...Technical Information PLUS 1 Connect CS100 IoT Gateway www danfoss com...

Page 2: ...on history Table of revisions Date Changed Rev October 2020 First edition 0101 Technical Information PLUS 1 Connect CS100 IoT Gateway Professional Install Only 2 Danfoss October 2020 BC299456869228en...

Page 3: ...lable variants functions 14 Operating modes 14 GNSS Global Navigation Satellite System 14 Wireless Solution 14 SIM card 14 Input output functions I O 14 CAN interfaces 15 Device configuration 15 CS100...

Page 4: ...Mounting Inside mount 23 Top Mount 23 Technical Information PLUS 1 Connect CS100 IoT Gateway Professional Install Only Contents 4 Danfoss October 2020 BC299456869228en 000101...

Page 5: ...anced knowledge in electrical engineering and fieldbus systems allowing them to estimate the risks and hazards of operating the device and to integrate it into systems with components of other manufac...

Page 6: ...0 1 2 3 4 5 1 Mounting holes 2 Housing 3 Status LED 4 Type label 5 8 Pin DEUTSCH connector C Caution This device is not field serviceable Opening the housing will void the warranty Indicator elements...

Page 7: ...tion of this device Never rely solely on wireless device for essential communications the CS100 is not designed for safety related applications This device is designed to be used in systems which must...

Page 8: ...k via LTE 4G Cat M1 additionally via GSM GPRS EDGE The interfaces are suitable for use in mobile and stationary systems for industry small business area and in agricultural and forestry machinery Feat...

Page 9: ...y with Regulation No 10 ECE Regulation No 10 Revision 3 14 08 2008 Approval No 10 R XXXXXX PTCRB This device has been certified for use on PTCRB Mobile Network Operator networks For more information s...

Page 10: ...er This device is designed to be used in systems which must be checked for conformity with legal requirements prior to placing into operation The integrator of this device is responsible to check and...

Page 11: ...depots chemical plants or where blasting operations are in progress Do not mount the antenna in the close environment of fuel tanks vessels with explosives and insufficiently shielded electronic devic...

Page 12: ...nstallation of the control system The following is recommended when welding on a machine equipped with electronic components Turn the engine off Remove electronic components from the machine before an...

Page 13: ...product and part numbers DEUTSCH mating connector bag assembly K29620 16 20 AWG Cable 1m with 8 pin DEUTSCH DTM connector 11222837 20 AWG Technical Information PLUS 1 Connect CS100 IoT Gateway Profess...

Page 14: ...hen GNSS sync is not available the local timing accuracy is 2 seconds per day Wireless Solution CS100 interfaces transmit data available on a CAN bus via LTE Cat M1 and 2G telecommunication services B...

Page 15: ...nsmitted and stored to the Danfoss Data Portal CS100 firmware update You can load a firmware update to the CS100 via the Danfoss PLUS 1 Connect portal The firmware update may reset the saved configura...

Page 16: ...y above 8 pin DEUTSCH CAN power supply local MFIO The table and drawing below show the pin assignment and conductor colors of the connector The colors stated in the table below are the conductor color...

Page 17: ...us network 2 ISO 11898 2 High Speed 2 0A B Multifunction Input Output 2 DIN AIN ResIN FreqIN CrntIN CL15 DOUT Radio Module LTE Cat M1 and 2G cellular Cat M1 Throughput UL DL Max 375 kbps Max 375 kbps...

Page 18: ...uency input middle range Description Unit Minimum Typical Maximum Comment Range Hz 0 10000 In steps of 1 Hz Range phase and quad Hz 0 5000 In steps of 1 Hz Rising voltage threshold V 3 89 Voltage requ...

Page 19: ...tal output Description Unit Minimum Typical Maximum Comment Output Voltage range V 0 10 3 22 3 Vin 12v 500ma Vin 24V 500ma Current mA 0 500 Each output pin capable of driving 500mA No current limiting...

Page 20: ...ice turns on The LED light correct sequence The LED lights up green constantly during the first second The LED starts to flash Problem with connection to PLUS 1 Connect portal After connecting to powe...

Page 21: ...the device unless temperature is between 40 C and 75 C 40 F and 167 F Do not store and or transport the device unless it is kept at a temperature between 40 C and 85 C 40 F and 185 F Disposal Observe...

Page 22: ...20 40 90 1 61 2 X 6 3 THRU 9 30 0 37 36 0 1 42 17 5 0 69 23 0 0 1 A A Minimal panel cutout CS100 Cable Pin 1 Pin 8 Pin 5 Pin 4 5 Meter 10 mm Technical Information PLUS 1 Connect CS100 IoT Gateway Pro...

Page 23: ...ess Provide strain relief for mating connector wires C Caution Module damage may occur Use caution when installing modules It s possible to damage the module if excessive pressure is applied during th...

Page 24: ...nfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distric...

Reviews: