Instruction
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
13
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
18. Mount the pump housing using the pin as
guide.
19. Press the housing down by hand and insert
the screws.
Alignment
hole
Guide pin
16. Place the screw in the center hole.
17. Tighten to a torque of 10
±
1 Nm.
20. Tighten the screws to a torque of 22 Nm.
21. Mount the two O-rings in the flange and
the O -ring on the front cover.