c)
Screw in remaining six screws (81) with washers (80) using a 13 mm
socket spanner,
25 ±
5 N·m [221 ± 44 in·lbf] or
80 ± 10 N·m [708 ± 89 in·lbf] for the 10 mm Hex key.
Installing LS end cover
1. Place spring stop (27) on the directional spool (25).
2. Place O-rings, 2x (57) and 2x (58) and spring stop (10) in end cover (65).
Service Manual
OSQA/OSQB
Assembly
©
Danfoss | July 2016
HN25D293 | AX00000127en-US0101 | 37