Dismantling amplifier spool
1.
Be careful not to damage the locking ring.
Carefully remove, from the amplifier spool (12), the locking ring (39) from the recess using a 3 mm
screwdriver.
a) Carefully guide the locking ring (39) back.
2.
Be careful not to damage the locking ring.
Carefully take the other locking ring (39) from the recess and guide it back using a 3 mm screwdriver.
Service Manual
OSQA/OSQB
Disassembly
©
Danfoss | July 2016