Installing OSQB back pressure valve
Fit spring (45) in position on piston (46) with Vaseline.
1. Place in assembled piston and spring.
2. Place in ball (48) in the piston (46).
3. Place O-ring (49.2) on plug (49).
a) Fit spring (47) in plug (49) with Vaseline.
b)
Screw in assembled plug and spring using an 8 mm
Hex key,
25 ± 3 N·m [221 ± 27 lbf·in].
Service Manual
OSQA/OSQB
Assembly
32 |
©
Danfoss | July 2016
HN25D293 | AX00000127en-US0101