4. Push locking ring (39) into position.
a) Place locking ring into the recess with ends facing away from pin holes.
Assembling priority valve spool
The priority valve spool has throttle/check valve (4) and orifice, dynamic (11).
1.
Screw in orifice, dynamic (11) using a 4 mm
Hex key and a
multigrip pliers, 5 ± 1 N·m.
Service Manual
OSQA/OSQB
Assembly
28 |
©
Danfoss | July 2016