background image

3

FRCC.ES.010.A4.ML

Manual

Controller Installation

Code (controller 

parameter o61 )* 

Model* Optyma Plus

TM

 New 

Generation

Code-no.

Compressor*

Refrigerant (controller parameter o30)*

settings are adjustable*

R404A 

(19)

R507 

(17)

R134a 

(3)

R407C 

(20)

R22

(2)

R407A**

(21)

R407F**

(37)

1

OP-MPHM007NFP00G

114X4101

NF7MLX

X

x

2

OP-MPHM010SCP00G

114X4102

SC10MLX

X

x

3

OP-MPHM012SCP00G

114X4104

SC12MLX

X

x

4

OP-MPHM015SCP00G

114X4105

SC15MLX

X

x

5

OP-MPHM018SCP00G

114X4109

SC18MLX

X

x

6

OP-MPGM034GSP00G

114X4210

GS34MFX

x

7

OP-MPHM026GSP00G

114X4214

GS26MLX

X

x

8

OP-MPHM034GSP00G

114X4229

GS34MLX

X

x

9

OP-MPZM030MTP00E

-

MTZ22-4VM

X

x

x

x

x

x

10

OP-MPZM048MTP00G

-

MTZ28-5VM

X

x

x

x

x

11

OP-MPZM048MTP00E

-

MTZ28-4VM

X

x

x

x

x

x

12

OP-MPZM060MTP00G

-

MTZ36-5VM

X

x

x

x

x

x

13

OP-MPZM060MTP00E

-

MTZ36-4VM

X

x

x

x

x

x

14

OP-MPZM086MTP00E

-

MTZ51-4VM

X

x

x

x

x

x

15

OP-MPZM086MTP00H

-

MTZ50-6VM

X

x

x

x

x

x

16

OP-MPZM108MTP00E

-

MTZ65-4VM

X

x

x

x

x

x

17

OP-MPZM108MTP00H

-

MTZ64-6VM

X

x

x

x

x

x

18

OP-MPZM136MTP00E

-

MTZ81-4VM

X

x

x

x

x

x

19

OP-MPZM136MTP00H

-

MTZ80-6VM

X

x

x

x

x

x

20

OP-LPHM018SCP00G

114X3109

SC18CLX.2

X

x

21

OP-LPHM026GSP00G

114X3217

GS26CLX

X

x

22

OP-LPHM048NTP00G

114X3225

NTZ48-5VM

X

x

23

OP-LPHM048NTP00E

114X3233

NTZ48-4VM

X

x

24

OP-LPHM068NTP00G

114X3241

NTZ68-5VM

X

x

25

OP-LPHM068NTP00E

114X3249

NTZ68-4VM

X

x

26

OP-LPHM096NTP00E

114X3357

NTZ96-4VM

X

x

27

OP-LPHM136NTP00E

114X3365

NTZ136-4VM

X

x

28

OP-MPUM034MLP00G

114X4261

MLZ015T5LP9

X

x

x

x

x

x

29

OP-MPUM034MLP00E

114X4264

MLZ015T4LP9

X

x

x

x

x

x

30

OP-MPUM046MLP00G

114X4281

MLZ021T5LP9

X

x

x

x

x

x

31

OP-MPUM046MLP00E

114X4284

MLZ021T4LP9

X

x

x

x

x

x

32

OP-MPUM068MLP00G

114X4308

MLZ030T5LC9

X

x

x

x

x

x

33

OP-MPUM068MLP00E

114X4311

MLZ030T4LC9

X

x

x

x

x

x

34

OP-MPUM080MLP00G

114X4321

MLZ038T5LC9

X

x

x

x

35

OP-MPUM080MLP00E

114X4324

MLZ038T4LC9

X

x

x

x

x

x

36

OP-MPUM108MLP00E

114X4344

MLZ048T4LC9

X

x

x

x

x

x

37

OP-MPUM125MLP00E

114X4414

MLZ058T4LC9

X

x

x

x

x

x

38

OP-MPUM162MLP00E

114X4434

MLZ076T4LC9

X

x

x

x

x

x

39

OP-LPHM215LLP00E

114X3476

LLZ024T4LC9

X

x

40

OP-LPHM271LLP00E

114X3482

LLZ033T4LC9

X

x

41

OP-MPUM057MTP00G

114X4290

MLZ026T5LP9

X

x

x

x

x

x

42

OP-MPUM057MTP00E

114X4293

MLZ026T4LP9

X

x

x

x

x

x

43

OP-LPHM067LLP00E

-

LLZ013T4LC9

X

x

44

OP-LPHM084LLP00E

-

LLZ015T4LC9

X

x

45

OP-LPHM098LLP00E

-

LLZ018T4LC9

X

x

46

OP-MPHM024AJP00G

114X4200

CAJ9513Z

X

47

OP-MPHM026AJP00G

114X4212

CAJ4517Z

X

48

OP-MPHM026AJP00E

114X4213

TAJ4517Z

X

49

OP-MPHM034AJP00G

114X4226

CAJ4519Z

X

50

OP-MPHM034AJP00E

114X4227

TAJ4519Z

X

51

OP-LPHM026AJP00G

114X3216

CAJ2446Z

X

52

OP-MPGM033AJP00G

114X4220

CAJ4511Y

x

53

OP-LPHM074FHP00G

114X3252

FH2511Z

X

54

OP-LPHM074FHP00E

114X3253

TFH2511Z

X

 

Code (controller parameter o61 )

: Code (contrôleur paramètre o61 / Code (Reglerparameter o61) / Kode (regulatorparameter o61)

Model

 : Modèle / Modell / Model

Code-no. 

: Code n° / Art-Nr. / Bestillingsnr.

Compressor

 : Compresseur / Verdichter / Kompressor

Refrigerant

 : Réfrigérant (contrôleur paramètre o30) / Kältemittel (Reglerparameter o30) / Kølemiddel (regulatorparameter o30)

*Settings are adjustable

 : parameters sont réglables / Werte einstellbar / indstillinger er justerbare

**Ongoing qualifications for condensing units

Optyma Plus™ condensing units are pre-parameterized, depending on the model of compressor 
mounted and the type of refrigerant. In the case of a “multi-refrigerant” compressor (e.g. MTZ or MLZ), 
the controller parameter “o30” for refrigerant is set to R404A and must be changed for other refrigerants 
(see chapter Commissioning - Quick start of the unit / Refrigerant change).

Annex

Summary of Contents for OP-LPHM018SCP00G

Page 1: ...Optyma PlusTM New Generation Controller Installation Manual http cc danfoss com...

Page 2: ...2 FRCC ES 010 A4 ML Manual Controller Installation English version 7 French version 12 German version 18 Danish version 24 Contents...

Page 3: ...x x x x x 33 OP MPUM068MLP00E 114X4311 MLZ030T4LC9 X x x x x x 34 OP MPUM080MLP00G 114X4321 MLZ038T5LC9 X x x x x x 35 OP MPUM080MLP00E 114X4324 MLZ038T4LC9 X x x x x x 36 OP MPUM108MLP00E 114X4344 M...

Page 4: ...s til ledning nr 6 Optyma Plus Verfl ssigungss tze sind vorparametriert f r das installierte Verdichtermodell und verwendete K ltemittel Im Fall eines Verdichters f r mehrere K ltemittel z B MTZ oder...

Page 5: ...Compressors limit switch Endschalter interrupteur 13 14 S1 2 X1 1 X1 N1 C1 BU BU BN N2 C2 PE BN N3 PE X1 BK BK 3 X1 BN BN BN P U 1 2 3 B2 22 X1 15 X1 20 X1 P B4 14 P B3 P 1 Option B5 2 BN BK GY I I I...

Page 6: ...unction 8 Day Night Function 8 Service and Maintenance 8 Main Display 8 Operating Parameters 8 Alarm and Error Messages 9 Repair 9 Controller failure 9 Factory reset 9 Controller Replacement of a unit...

Page 7: ...Plus new generation is preset depending on the compressor model and refrigerant type In the case of a multi refrigerant compressor the controller of the condensing unit is set for R404A see table on...

Page 8: ...r 06 00 a m Select and set parameter t18 Night start hours e g 022 for 22 00 p m Select and set parameter t07 Clock setting hours e g 011 for 11 xx a m Select and set parameter t08 Clock setting minut...

Page 9: ...terminal block from the controller or remove the complete controller Connect the condensing unit back to power supply turn hardware main switch on Controller failure if the controller fails there is a...

Page 10: ...Reference 8 0K The Reference is accessible by pressing short the middle button of the controller When Reference is shown it can be modified with the upper or lower button Additionally to this the cont...

Page 11: ...ction pres Param c75 Scroll 1 4bar Recip 0 4bar Low pressure switch Cut In Scroll 1 5bar Recip 0 5bar Suction Pressure Electronic Safety LP Mechanical Safety LP High pressure switch Cut In Scroll and...

Page 12: ...tr leur Affichage permanent 14 Visualisation des param tres de fonctionnement 14 Alarmes et messages d erreur 15 D pannage 15 D faillance du contr leur 15 R initialisation du param trage usine 15 Remp...

Page 13: ...es bornes Connectez l alimentation lectrique au sectionneur principal conform ment au sch ma lectrique situ sur la face interne de la porte avant Connectez l alimentation lectrique au sectionneur prin...

Page 14: ...param tre c33 Scroll 1 7bar Piston 0 7bar c76 Scroll ou Piston 0 7bar Pression basse pressostat Cut Out Scroll 0 5bar Piston 0 3bar Pression basse transducteur Cut Out param tre c75 Scroll 1 4bar Pist...

Page 15: ...aillance du contr leur En cas de d faillance du contr leur il est possible de faire fonctionner le groupe de condensation en mode manuel moyennant quelques adaptations mineures Pour ce faire effectuez...

Page 16: ...sur le bouton du milieu du contr leur A ce stade en appuyant sur le bouton du haut ou du bas la valeur usine 8 0K est augment e bouton du haut ou diminu e bouton du bas chacune des impulsions exerc e...

Page 17: ...asse transducteur param tre c75 Scroll 1 4bar Piston 0 4bar Pression basse pressostat Cut In Scroll 1 5bar Piston 0 5bar Pression d aspiration S curit Electronique BP S curit M canique BP Pression hau...

Page 18: ...on 20 Instandhaltung und Wartung 20 Displayanzeige 20 Betriebsparameter 20 Alarm und Fehlermeldungen 21 Reparatur 21 Reglerdefekt 21 Zur cksetzen auf Werkseinstellungen 21 Regleraustausch bei einer Ei...

Page 19: ...former ab Werk Raumthermostat an diese Klemmen anschlie en Stromversorgung mit Hauptschalter verbinden wie im Schaltplan auf der Innenseite der Frontt r gezeigt Stromversorgung mit Hauptschalter verbi...

Page 20: ...006 f r 6 00 Uhr W hlen und setzen Sie Parameter t18 Beginn Nacht Stunden z B 022 f r 22 00 Uhr W hlen und setzen Sie Parameter t07 Einstellung Uhr Stunden z B 011 f r 11 xx Uhr W hlen und setzen Sie...

Page 21: ...Schlie enSiedenVerfl ssigungssatzwiederandieStromversorgungan drehenSiedenGer tehauptschalter in die Ein Position Reglerdefekt F r den Fall dass der Regler ausf llt kann der Verfl ssigungssatz manuell...

Page 22: ...rehzahlbestimmt Werkseinstellung der Referenz 8 0 K Um auf die Referenz zuzugreifen bet tigen Sie kurz die mittlere Taste am Regler Wenn die Referenz angezeigt wird kann sie ber die obere oder untere...

Page 23: ...roll 1 4 bar Hubkolbenv 0 4 bar Niederdruckschalter Ein Scroll 1 5 bar Hubkolbenv 0 5 bar Saugdruck Sicherheit Elektronik Niederdr Sicherheit Mechanik Niederdr Hochdruckschalter Ein Scroll und Hubkolb...

Page 24: ...on 26 Service og vedligeholdelse 26 Hovedvisning 26 Driftsparametre 26 Alarm og fejlmeddelelser 27 Reparation 27 Regulatorfejl 27 Fabriksreset 27 Udskiftning af regulator for et aggregat p stedet 28 R...

Page 25: ...den midterste knap for at f vist v rdien for det valgte parameter Tryk derefter p den verste eller nederste knap for at indstille v rdien af det valgte parameter Et langt tryk p disse knapper skifter...

Page 26: ...meter t17 dagstart timer f eks 006 for kl 6 00 V lg og indstil parameter t18 natstart timer f eks 022 for kl 22 00 V lg og indstil parameter t07 indstilling af ur timer f eks 011 for kl 11 xx V lg og...

Page 27: ...onter den store terminalblok fra regulatoren eller afmonter hele regulatoren Tilslut kondenseringsaggregatet til str mforsyningen igen sl hovedafbryder for hardware til Regulatorfejl hvis regulatoren...

Page 28: ...or reference 8 0 K Referencen er tilg ngelig ved kort tryk p regulatorens midterste knap N r referencen vises kan den modificeres med verste eller nederste knap Ud over dette kan reguleringen af konde...

Page 29: ...yk Param c75 Scroll 1 4 bar stempel 0 4 bar Lavtryksafbryder Indkobling Scroll 1 5 bar stempel 0 5 bar Sugetryk Elektronisk sikkerhed LP Mekanisk sikkerhed LP H jtryksafbryder Indkobling Scroll og ste...

Page 30: ...e speed technology specialists Today we operate from engineering and manufacturing facilities spread across three continents FRCC ES 010 A4 ML October 2014 replace FRCC ES 010 A3 ML July 2014 Copyrigh...

Reviews: