34-40 Actual inputs
Range:
Function:
000000
000000
*
[00000000000 /
111111111111]
During a positioning sequence the “Referenced position
reached” output (X59 2) is set according to this parameter.
READ-ONLY PARAMETER:
This parameter displays the last read status of the digital input
on the option card (X57). The status of the digital inputs on the
VLT5000 control card is accessible via par. 16-60.
34-56 PID tracking error
Range:
Function:
0
*
[–2,000,000,000 …
2,000,000,000 UU]
During a positioning sequence the “Referenced position
reached” output (X59 2) is set according to this parameter.
READ-ONLY PARAMETER:
The current PID tracking error is displayed in this parameter in
user units.
MCO351 Positioning Controller
4. Programming
MG.33.R1.02 - VLT
®
is a registered Danfoss trademark
33