Ordering specification chart

A wide range of options to the basic control handle allow custom-tailoring to each application. The
following ordering specification chart is provided for assistance in determining model number. Other
options are possible, consult Danfoss with further questions.

Ordering specification chart

MCH

X

X

X

X

X

XXX

Mounting option

Control knob type

Handle actuation

Electrical

characteristics

Connector

Factory assigned

Mounting option

Code

Description

Detail

1

Base (surface) mount aluminum case

Four screws connect to the flanges on the bottom of the metal case.

2

Top mount (drop in) with plastic case

Two screws connect to an enlarged mounting plate.
Top mounting allows the entire handle to be removed from above the panel.
The case is made of black nylon plastic.

3

Top mount (drop in) without case

Two screws connect to an enlarged mounting plate.
Top mounting allows the entire handle to be removed from above the panel.

4

Panel mount with plastic case

Four screws connect to the top plate that holds the boot in place.
The case is made of black nylon plastic.

5

Panel mount without case

Four screws connect to the top plate that holds the boot in place.

Control knob option

Code

Description

Detail

1

Non-locking

The friction-held handle detents with a springloaded ball to indicate null, while
the spring-return handle has a spring preload indicating null.The non-locking
handle has a standard ball knob.

2

Center lock

The non-locking handle has a standard ballThe center lock handle has a

cylindrical knob and provides a positive center lock that unlatches when the

operator pulls up on the knob.

3

Non-locking, auxiliary push button switch

This knob is teardrop shaped, with an auxiliary momentary push-button switch on
top.
The switch is wired through the handle shaft to the body with three wires
(common, normally open, and normally closed).

5

Non-locking, no knob

The customer provides customized knob.

6

Three position maintained rocker switch

The cylindrical knob has a boot covering the three-position switch in the knob.
The switch, wired through the handle, is used for auxiliary functions.

8

*

Special (no handle or knob)

9

Three position momentary rocker switch

This is the same as option 6, but the switch returns to the center position when

released.

*

 Unique configuration, for details contact your Danfoss representative.

Reference 

Dimensions

.

Handle actuation option

Code

Description

Detail

A

Spring return, bi-directional

This handle uses a torsion spring to return to the mechanical center position and

has 30 degrees of handle throw on either side of center.

B

Friction held, bi-directional

This handle has an adjustable drag, set with a clamp-type brake that holds the

handle at the set position and has 30 degrees of handle throw on either side of

the center detent.

Technical Information

MCHXXX

Ordering information

 

©

 Danfoss | February 2017

11022667 | BC00000033en-US0601 | 5

Summary of Contents for MCH19AM1649

Page 1: ...Technical Information MCHXXX Control Handle powersolutions danfoss com...

Page 2: ...ded to Danfoss layout FA January 2011 Various updates EA May 2010 MCHXXX Potentiometer Models with 1K Ohm table updated DA February 2010 MCHXXX Potentiometer Models with 1K Ohm table updated CA August...

Page 3: ...ntal testing 9 Installation Dimensions 10 Connectors 10 Wiring 11 Connection diagrams Potentiometer option 14 Potentiometer option with 1K Ohm potentiometer 14 PWM Option primarily 15 PWM option perfo...

Page 4: ...c parameters Features Shock and vibration resistant Choice of three mounting styles with or without watertight case Rugged components designed for the construction environment High torque handle actua...

Page 5: ...spring preload indicating null The non locking handle has a standard ball knob 2 Center lock The non locking handle has a standard ballThe center lock handle has a cylindrical knob and provides a pos...

Page 6: ...proportional 24 VDC Same as option F except this handle runs on a supply voltage of 24 Vdc H Switching This handle is non proportional Moving the handle off null activates switches that power ON OFF...

Page 7: ...ires from the case terminate in a sealed Delphi connector 8 Pigtail sealed DEUTSCH connector The wires from the case terminate in a sealed DEUTSCH connector Pigtail or leadwire is routed from the cont...

Page 8: ...nd above friction drag 1 1 N m 10 lbf in Friction drag 1 5 3 N m 13 5 3 lbf in Friction is adjusted at the brake with a 5 32 inch internal hex wrench and 3 8 inch open end hex wrench Step Plus Proport...

Page 9: ...cifications IP 65 equivalent Vibration Withstands a vibration test designed for mobile equipment controls consisting of two parts 1 Cycling from 5 to 2000 Hz in each of the 3 axes 2 Resonance dwell fo...

Page 10: ...2 38 121 3 max 4 78 121 3 max 4 78 Top drop in mount Customer panel Tapping screws 2 30 ref 30 ref 30 ref 30 ref 30 ref 30 ref 30 ref 30 ref 302 0 max 11 88 121 0 max 4 76 121 0 max 4 76 120 0 max 4 7...

Page 11: ...minal labeled common The switch terminals are 3 16 inch quick connect PWM Option primarily on page 15 shows a pre wired control handle with center off switch and Delphi connector exhibiting the handle...

Page 12: ...lockwise increases output PWM MCHXXX option reached its end of life cycle in 2008 and is no longer available L control handles Standard L Threshold adjustment Counter clockwise increases output Forwar...

Page 13: ...Clockwise increases output Reverse full stroke Clockwise increases output Acceleration deceleration ramp Clockwise increases time Option L Electronic PWM auxiliary switching 12 Vdc reached its end of...

Page 14: ...with electrical displacement controls EDCs Whether two or single pots both require the same electrical connection to the EDC and only one of the dual coils needs to be connected to achieve forward an...

Page 15: ...11181083 MCH41BB1648 X X X X MCH41BM1504 X X X X X X MCH41AB1648 X X X X 11068165 MCH42BB1644 X X X X X MCH51AM1497 X X X X X X 11017769 MCH51BB1535 X X X X MCH51BD1517 X X X X MCH52BM1497 X X X X X X...

Page 16: ...ot switched 24 Vdc models Center deadband optional 3 nominal Full stroke current capability Step current Step current occurs at end of deadband Customer specified Reference Ordering Information Techni...

Page 17: ...nesota 55447 For devices in need of repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number Technical Inf...

Page 18: ...Technical Information MCHXXX 18 Danfoss February 2017 11022667 BC00000033en US0601...

Page 19: ...Technical Information MCHXXX Danfoss February 2017 11022667 BC00000033en US0601 19...

Page 20: ...tions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Sha...

Reviews: