5
VIFZT102 © Danfoss 03/2013
Installation Guide
Danfoss Link™ SCM
Green LED ON
Away OFF
Red LED ON
Away ON
Green LED fast flash
Adding or link test
Green LED short flash
Ready for adding
Red LED slow flash
for 5 seconds
Adding not OK
Red LED slow flash
continously
Transmission test not OK or lost
connection to Danfoss Link™ CC
Status indicator
Turn off the power to the device, then press and hold the install
button in front of the device for approx . 5 seconds while the
power is switched on again . The button must be held until LED
gives a red flash .
Factory reset
Once the Danfoss Link™ SCM and all other
devices in the system have been registered
and the Danfoss Link™ CC is placed in its final
position, perform a full
network test
(see
separate Danfoss Link™ CC manual) .
Perform network test
Transmission test (optional)
Initiate a transmission test on the Danfoss Link™ SCM by pressing
and holding the install button for more than 2 seconds . If the test
is satisfactory the green LED will flash and a message is displayed
on the Danfoss Link™ CC . If the test fails the red LED will slow
flash continuously .
GB