VIFZT102           © Danfoss          03/2013

Installation Guide 

Danfoss Link™ SCM

Introduction   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

Installation    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

Mounting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

Wiring   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

Adding the device    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

Perform network test .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

Transmission test (optional)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

Factory reset  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

Status indicator   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

Getting started with Danfoss Link™ SCM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8

Technical specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9

Disposal instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9

Table of Contents

Summary of Contents for Link SCM

Page 1: ...MAKING MODERN LIVING POSSIBLE Danfoss Heating Solutions Danfoss Link SCM Simple Communication Module Installation Guide ...

Page 2: ...Introduction 5 Installation 5 Mounting 5 Wiring 6 Adding the device 6 Perform network test 7 Transmission test optional 7 Factory reset 7 Status indicator 7 Getting started with Danfoss Link SCM 8 Technical specifications 9 Disposal instructions 9 Table of Contents ...

Page 3: ... The Danfoss Link wireless system s transmission range is suf ficient for most applications however each building has different obstacles affecting communication and maximum transmission distance If communication problems occur Danfoss suggests to support the system with repeaters In exceptional cases the wireless system may not be suitable for your installation Note Be aware that installation and...

Page 4: ... flash If adding is successful the LED turns green HOME or red AWAY permanently depending on input stage For further information see the Danfoss Link CC installation guide Note If adding the Danfoss Link SCM to the Danfoss Link CC is unsuccessful make sure the right Danfoss Link CC software version is applied Correct version 2 5 57 or higher Adding the device 1 2 PWR NC COM PWR Note Refer to the D...

Page 5: ... 5 seconds while the power is switched on again The button must be held until LED gives a red flash Factory reset Once the Danfoss Link SCM and all other devices in the system have been registered and the Danfoss Link CC is placed in its final position perform a full network test see separate Danfoss Link CC manual Perform network test Transmission test optional Initiate a transmission test on the...

Page 6: ... Danfoss Link CC the AWAY mode is indicated by the suitcase icon After 10 minutes the AWAY mode screen will be replaced by the Standby screen for security reasons Send another text message 0000 1 to revert the system to the HOME mode ON The LED turns green and the AWAY icon disappears See the Danfoss Link MPB User Manual for further information Smartphone app For Android phones and iPhones you can...

Page 7: ...tage Net adapter 220 240 V 50 Hz Standby consumption 0 9 W Ambient temperature 0 to 45 C Transmission frequency 868 42 MHz Transmission range in normal buildings Up to 30 m Transmission power Max 1 mW Pollution degree 2 Ball pressure test temperature 75 C Software classification Class A IP class 20 Dimensions 80 80 30 mm Disposal instructions GB ...