Technical Information
KPP PPU
11029257
• Rev BB • July 2013
9
**Do not attempt to apply a quadrature output PPU without first consulting with a Sauer-
Danfoss field applications engineer for specific application requirements.
KPP
X
X
X
X
XX
Hall effect PPU
Revision
Mechanical configuration (housing)
1
Flat end
2
Conical end
3
Conical end, fixed position
4
Flat end, fixed position
Electrical configuration
2
Regulated supply 4.5 to 8.5 Vdc, 3 connection,
non-directional, wire fault detection
3
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current
4
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault on speed signal, open collector on direction signal
5
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional wire
fault detection, high current, filtered speed output
6
Battery supply 7 to 32 Vdc, 3 connection, non-directional,
limited wire fault detection
7
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current, quad output**
8
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, low current, output signal divided by 2
9
Regulated supply 4.5 to 8.5 Vdc, 4 connection, directional,
wire fault detection, high current, quad output**
A
Battery supply 7 to 32 Vdc, 4 connection, directional, limited
wire fault detection, high current, quad output**
B
Regulated supply 4.5 to 8.5 Vdc, 3 connection, non-
directional, wire fault detection, high current, filtered speed
output
Electrical connector
1
Amp Mate-n-Lok
4
1
Delphi/Packard Weather-Pack (3 pin)
2
Delphi/Packard Weather-Pack (4 pin), used when direction signal is required
5
Delphi/Packard Metri-Pack
6
Integral Turck Eurofast (no leadwires)
7
1
Deutsch DT04 (3 pin)
2
Deutsch DT04 (4 pin), used when direction signal is required
8
Delphi/Packard Metri-Pack 150 series plug
9
Delphi/Packard Metri-Pack 150 series jack
All leadwire length is described in inches unless denoted with
m
(meters)
Specialties
A
Special connector pinouts
B
Special connector pins
Ordering Nomenclature