9
Table A. Hidden Access Configuration Variables.
HIDDEN ACCESS
(continued)
DIAGNOSTIC MESSAGES
The control console can recognize many of the faults or
errors which may potentially occur in the sensors, valves,
operator console or wiring. It will report the condition on one
or both displays, sound the alarm and may shut the control
down if faulty machine operation is possible.
Faults may inhibit or stop valve drive when in auto mode but
will not in manual mode. Faults will clear when the cause is
repaired or eliminated.
The KGS console is pre-programmed with 21 diagnostic
English messages which aid the operator in taking corrective
action. For faults which do not turn valve drive off, the display
fault message alternates with the normal operating
information.
Configuration
Descripton Of
Range Of Values
S u g g e s t e d
S u g g e s t e d
V a r i a b l e
Configuration Variable
D e f a u l t
Access Level
Battery
Control voltage supply
12V, 24V
24V
Dealer
Alarm
Audible alarm switch
off/on
on
Foreman
Displayed units
Distance measure units
in,ft,mm
in
Foreman
Slope sensor configuration Quantity of slope sensors used
single, dual
single
Factory
Left side wand hub
Hub location for grade sensor
left, right
left
Foreman
Right side wand hub
on left side or right side
left, right
right
Foreman
Valve type
Tow point valve type
servo, on/off, proportional
proportional Dealer
Coil/drive type
Tow point valve coil wiring
dual lo, dual hi, single
dual hi
Dealer
Application
Machine type software
planer, paver
paver
Factory
Interlock
Motion sensor type
none, external, speed, switch
external
Factory
(motor PPU or handle switch)
Display configuration
No. of alpha/numeric displays
single, dual
single
Factory
PPU pulses
Motor speed pickup pulses
200-30,000
10,000
Dealer
per 1000 ft or per 300 m
Interlock travel speed
Machine speed to turn control
0.0 to 20.0 ft/min or 0 to 7.0m/min 10.0 ft/min
Dealer
on or off
Switch interlock delay
Time delay after forward motion
0.0 to 10.0 sec
10.0 sec
Dealer
switch to turn control on
Front slope sensor weight
Effective position of slope sensor 0 to 100%
50%
Foreman
(from front sensor)
Slope error deadband
Slope error at start of valve drive 0.0% to 100%
0.00%
Foreman
Wand error deadband
Grade error at start of valve drive 0.0 in to 1.0 in or 0.0 to 25.0 mm
.02 in
Foreman
Ultrasonic error deadband Grade error at start of valve drive 0.0 in to 1.0 or 0.0 to 25.0 mm
.04 in
Foreman
Wand error limit
Grade error at valve drive hold
.10 to 4.0 in or 2.0 to 100 mm
1.0 in
Foreman
Ultrasonic error limit
Grade error at valve drive hold
.10 in to 4.0 in or 2.0 to 100 mm
1.0 in
Foreman
Servo frequency
PWM frequency for servo valve
100 to 200 Hz
200 Hz
Dealer
On/off frequency
Pulse frequency for time
1 to 10 Hz
5 Hz
Dealer
proportional valve
Proportional frequency
PWM frequency for proportional
40 to 160 Hz
150 Hz
Dealer
solenoid valves
Left side raise valve step
Valve voltage % at start of raise
0 to 60%
35%
Foreman
(servo or proportional ) leftside
Right side raise valve step Valve voltage % at start of raise
0 to 60%
35%
Foreman
(servo or proportional ) right side
Left side lower valve step
Valve voltage % at start of lower 0 to 60%
35%
Foreman
(servo or proportional ) left side
Right side lower valve step Valve voltage % at start of lower 0 to 60%
35%
Foreman
(servo or proportional ) right side
Left side raise on/off
Valve on time at start of raise
1 to 50 msec
20 msec
Dealer
valve step
left side
Right side raise on/off
Valve on time at start of raise
1 to 50 msec
20 msec
Dealer
valve step
right side
Left side lower on/off
Valve on time at start of lower
1 to 50 msec
20 msec
Dealer
valve step
left side
Right side lower on/off
Valve on time at start of lower
1 to 50 msec
20 msec
Dealer
valve step
right side