2

PART NUMBER CONFIGURATION

Hardware Configuration Table.

Road Sentry Console

Revision Letter

Control Application
(1)

 Asphalt paver

(2)

 Planer, reclaimer

Controller Outputs
(5)

 Solenoid or servovalve, high side switch

(6)

 Solenoid, low side switch

Display Configuration
(1)

 One setting/message display, non-backlit switches

(2) 

Two setting/message displays, non-backlit switches

(3)

 One setting/message display, backlit switches

(4)

 Two setting/message displays, backlit switches

Special Configuration

00 and as required

Mounting Configuration
(5)

 Bottom flange mount

(6)

 1/2-13 side studs *

*  Consult factory for availability

 K G S  A              X X

To assist in configuring the hardware for the Road Sentry Console, determine the correct part number from the table below.

Contact Danfoss for assistance in specifying the required software.

Control Application

1. Asphalt paver control software is compatible with a 10

inch grade wand. Machine travel is 4 inches above and

1 inch below the setup reference zero. When resetting

auto  mode  (from  manual  mode)  the  prior  setpoint  is

saved  and  resumed.  The  machine  will  automatically

return to the previous setpoint.

2. Planer, reclaimer control software is compatible with a

25 inch grade wand. Machine travel is 10 inches below

and 2.5 inches above the setup reference zero. Actuating

the up/down toggle switch places the control in manual.

When resetting auto mode (from manual mode) the prior

setpoint is not saved but must be reset by the operator.

The motion interlocks are disabled with this option.

Controller Outputs

5. Solenoid valve or servovalve, high side switched. The

controller output is designed to drive servovalves, on/off

or proportional solenoid valves with the two valve coils

permanently grounded.

6.  Solenoid valve, low side switched. The controller output

is  designed  to  drive  on/off  or  proportional  solenoid

valves  with  the  two  valve  coils  permanently  tied  to

battery “+”.

Display Configuration

1. One  setting/message  display.  The  eight  character

alphanumeric display is used for both setpoint position

and actual position. The setpoint/actual switch controls

which value is displayed. Switches are not backlit.

2. Two setting/message displays. The faceplate has one

eight character display for setpoint position and one for

actual  position.  There  is  no  setpoint/actual  switch.

Switches are not backlit.

3. One  setting/message  display,  backlit  switches.  The

backlit switch configuration features illumination behind

each push switch that makes them night-readable. A

photo sensor turns the backlight on and off.

4. Two  setting/message  displays,  backlit  switches.  The

backlit switch configuration features illumination behind

each push switch that makes them night-readable. A

photo sensor turns the backlight on and off.

Mounting Configuration

5. Bottom flange mount. This requires a flat surface with

two holes for 5/16 inch diameter fasteners.

6. 1/2-13 side studs. This requires a yoke with slots for the

studs.

Summary of Contents for KGS

Page 1: ...es or proportional solenoid valves Fault recognition with diagnostics Full electrical and environmental protection Fewerelectricalaccessoriesandreducedmachine wiring possible SYSTEM CONFIGURATION The...

Page 2: ...uto mode from manual mode the prior setpoint is not saved but must be reset by the operator The motion interlocks are disabled with this option Controller Outputs 5 Solenoid valve or servovalve high s...

Page 3: ...l current CAN CONNECTION Two wire shielded cable Consult Danfoss ENVIRONMENTAL OPERATING TEMPERATURE 40 to 70 C 40 to 158 F MOISTURE Protected against 95 relative humidity Packaged to withstand high p...

Page 4: ...4 DIMENSIONS Dimensions of the KGS in Millimeters Inches 1961...

Page 5: ...s The mating connector assembly for the KGS console must be ordered separately The Danfoss part number is K18169 which is composed of 28 pins 8 seal plugs 1 connector and 3 connector keys 9 8 7 6 5 4...

Page 6: ...rmined by built in software and by instructions received from the operator s use of switches Continuous operating information is provided to the operator with displays which are continuously monitorin...

Page 7: ...effective reference point Both setpoint and actual displays are changed simultaneously Holding this switch and pushing the null setpoint switch will alternately zero the display offset or zero the dis...

Page 8: ...variables to a particular hidden access level is accomplished with the special configuration section of the ordering code Consult Danfoss The foreman level is accessed with the sensitivity switch and...

Page 9: ...m Interlock travel speed Machine speed to turn control 0 0 to 20 0 ft min or 0 to 7 0m min 10 0 ft min Dealer on or off Switch interlock delay Time delay after forward motion 0 0 to 10 0 sec 10 0 sec...

Page 10: ...repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Departm...