5
ROAD SENTRY SYSTEM CONFIGURATION DIAGRAM
1957
KGS
CONTROL
CONSOLE
KGS
CONTROL
CONSOLE
KUS
ULTRASONIC
GRADE SENSOR
MOTION
INPUT
CONTROL
VALVE
MCX104A
SLOPE
SENSOR
CONTROL
VALVE
MCX104A
OPTIONAL
SENSOR
KUS
ULTRASONIC
GRADE SENSOR
MCX103A
WAND
GRADE
SENSOR
MCX103A
WAND
GRADE
SENSOR
ELECTRICAL CONNECTION
See the Connector Diagram. A 28-pin ITT Cannon connector provides all input and output to the KGS Controller per the table
below. See the Road Sentry System Configuration Diagram for a pictorial view of the system level connections.
The mating connector assembly for the KGS console must be ordered separately. The Danfoss part number is
K18169, which is composed of 28 pins, 8 seal plugs, 1 connector and 3 connector keys.
9
8
7
6
5
4
3
2
1
19
18
17
16
15
14
13
12
11
10
28
27
26
25
24
23
22
21
20
1843
Pin Orientation Shown is for the Device, not the Mating, Connector.
CONNECTOR DIAGRAM
P i n Function
P i n Function
P i n Function
1 B
10 Ground
20 N/C
2 Valve raise
11 Ground
21 N/C
3 Valve lower
12 Ground
22 Sensor power
4 PPU/travel
13 Ground
23 Sensor power
5 Analog in 0
14 Ground
24 Sensor power
6 Analog in 1
15 Ground
25 CAN address 0
7 CAN shield
16 Ground
26 CAN address 1
8 CAN low
17 Ground
27 CAN address 2
9 CAN high
18 Ground
28 CAN address 3
19 Ground