Electrical specifications
JS6000 potentiometer sensor with analog output
Supply voltage (Vs)
< 36 Vdc
Maximum survival voltage
36 Vdc
Maximum wiper current
5 mA
Maximum load current
200 mA resistive
Center tap/switch alignment
Within 0.5˚
Potentiometer electrical angle
± 18˚
Center tap angle
± 2.5˚
Insulation resistance at 50 Vdc
> 50 MΩ
Potentiometer output options
Minimum voltage
(% Vs)
Maximum voltage
(% Vs)
Switch track angle
(°)
Resistance (KΩ)
Model code order
character
10 ± 2
90 ± 2
± 1.5
1.6 to 2.4
RR
25 ± 2
75 ± 2
± 1.5
2.2 to 3.6
10 ± 2
90 ± 2
± 5
1.6 to 2.4
SS
25 ± 2
75 ± 2
± 5
2.2 to 3.6
TT
Dual potentiometer output
Minimum voltage
(% Vs)
Maximum voltage
(% Vs)
Switch track angle
(°)
Resistance (KΩ)
Model code order
character
10 ± 2
90 ± 2
± 1.5
1.6 to 2.4
UU
JS6000 Hall effect sensor with analog output
Supply voltage (Vs)
5 ± -0.5 Vdc
Maximum survival supply voltage
5 Vdc
Maximum current draw (base only)
90 mA
Minimum output voltage
6% to 14% Vs
Center voltage
48% to 52% Vs
Maximum output voltage
86% to 94% Vs
Electrical Installation
JS6000 Analog Output
Product overview
6 |
©
Danfoss | May 2017
BC00000013en-US | 0201