background image

IKORE B detailed description

Technical data

Description

Value

Stop function

Cat. 3-Ple EN12849-1 and SIL 3 IEC 61508 / IEC 62061

Ingress Protection rating

IP65/NEMA4

Anti-condensation system

N/A

Frequency band

2405MHz to 2475MHz 20dBm/100mW

Main mechanisms (maximum)

Push button (7) + START+ STOP

Range (Normal Conditions)

100m

Auxiliary mechanisms

N/A

Removable EEPROM

External

Battery model

BT11K

Battery life

8hr (100% duty cycle)

Operating temperature range

-20 °C to 70 °C (-4 °F to 158 °F)

Storage Temperature Range (24h)

-25ºC to 75ºC (-13ºF to 167ºF)

Storage Temperature Range (long periods)

-25ºC to 55ºC (-13ºF to 131ºF)

Relative Humidity

max. 95% without condensation

Weight (with battery)

315 grams

Dimensions LxWxH mm

174.5x68x56

Harness

Hand strap/shoulder strap

Display

N/A

Cable connector

N/A

Range limiter

N/A

Associated receivers

R11

User Manual

IKORE B Transmitter

Technical description

 

8 | 

©

 Danfoss | May 2021

BC292582855621en-000201

Summary of Contents for IKORE B

Page 1: ...User Manual Remote Control IKORE B Transmitter www danfoss com...

Page 2: ...visions Date Changed Rev May 2021 Battery information updated technical information corrected 0201 January 2019 Rebranded to Danfoss Power Solutions 0101 User Manual IKORE B Transmitter 2 Danfoss May...

Page 3: ...ion 8 Maintenance Maintenance tips 9 Troubleshooting 2 4GHz 9 Charger and battery Charger and battery 10 BC70K and BT11K specifications 10 BC70K Battery Charger Set up 10 BC70K Charger LEDs Status 11...

Page 4: ...r the product Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX RATEX certified to work in such conditions IKORE B Safety Warnings Potential damage to o...

Page 5: ...erated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interf...

Page 6: ...s LEDs 2 Hoist selection LEDs 3 Maneuver push buttons 4 STOP button 5 External and extractable EEPROM module 6 Rechargeable Li Ion batteries BT11K 7 START push button 8 Hoist selection push button Use...

Page 7: ...on The LED will blink green until the transmitter is linked with the receiver RX I II RX I I II II Data sheet I II 1 I II When the receiver confirms the link the status LED will turn to a fixed green...

Page 8: ...OM External Battery model BT11K Battery life 8hr 100 duty cycle Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to 167 F Storage Temperature Range...

Page 9: ...ting 2 4GHz Color and frequency Pulse frequency Description Action Blue fast pulses Starting the system establishing communications with radio and EEPROM Wait Blue continuous Stand by mode Set up syst...

Page 10: ...ng temperature 0 C to 45 C Discharge temperature 20 C to 60 C Charging mode Fast 2 5 h and intelligent Weight 23 g BC70K Battery Charger Set up The battery charger has two charging compartments that c...

Page 11: ...batteries and battery charger follow these recommendations Do not recharge the battery until it is completely flat as shown with red LED slow pulse on the transmitter Always charge the batteries at te...

Page 12: ...BC70K Battery Charger Dimensions Dimensions mm 97 15 103 31 30 10 23 50 127 90 2 57 User Manual IKORE B Transmitter Charger and battery 12 Danfoss May 2021 BC292582855621en 000201...

Page 13: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...