IKORE B General Safety

The following safety instructions must be read carefully to install and use the product properly, and to

keep it in perfect working condition, and to reduce the risk of misuse.

Strictly adhere to the installation instructions contained in this document.

Make sure that professional and competent personnel carry out the installation.

Ensure that all site and prevailing safety regulations are fully respected.

Make sure that this document is permanently available to the operator and maintenance personnel.

Keep the transmitter out of reach of non-authorized personnel.

Remove the transmission key when the set is not in use.

Check each working day the STOP button and other safety measures. When in doubt, press the STOP
button.

Whenever several sets have been installed, make sure the transmitter is the right one. Identify the
machine controlled on the label for this purpose on the transmitter or by using the display (in case it
has one).

Service the equipment periodically.

When carrying out repairs, use spare parts supplied by Danfoss only.

W

Warning

Potential damage to the operator or the product. Do not use this product on machines in potentially
explosive atmospheres unless the model is ATEX/RATEX certified to work in such conditions.

IKORE B Safety Warnings

Potential damage to operator and product.
Follow the guidelines below to reduce risk of injury to the operator and the product.

Use the device with the manufacturer's battery and battery charger (if applicable).

Only allow qualified personnel to operate the equipment.

Always set the STOP button in the off position when not in use.

Always press STOP before plugging in tether cable (if applicable).

Remove the Tether connection on the transmitter First (if applicable).

Do not operate product when visibility is limited.

Make sure product is compatible with the machine.

Avoid knocking or dropping the product.

Do not use the product if a failure is detected.

Changes or modifications not approved by Danfoss can void the user's authority to operate this product.

Quick reference precautions

Tx Cr 1

Cr 1

Remove the EEPROM in order

to disable the transmitter

When in doube, press the

STOP button

Make sure the transmitter

works with the machine

to be handled

Do not use the set when

visibility is limited

Avoid knocking or dropping

the set

User Manual

IKORE B Transmitter

Safety instructions

 

4 | 

©

 Danfoss | May 2021

BC292582855621en-000201

Summary of Contents for IKORE B

Page 1: ...User Manual Remote Control IKORE B Transmitter www danfoss com...

Page 2: ...visions Date Changed Rev May 2021 Battery information updated technical information corrected 0201 January 2019 Rebranded to Danfoss Power Solutions 0101 User Manual IKORE B Transmitter 2 Danfoss May...

Page 3: ...ion 8 Maintenance Maintenance tips 9 Troubleshooting 2 4GHz 9 Charger and battery Charger and battery 10 BC70K and BT11K specifications 10 BC70K Battery Charger Set up 10 BC70K Charger LEDs Status 11...

Page 4: ...r the product Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX RATEX certified to work in such conditions IKORE B Safety Warnings Potential damage to o...

Page 5: ...erated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interf...

Page 6: ...s LEDs 2 Hoist selection LEDs 3 Maneuver push buttons 4 STOP button 5 External and extractable EEPROM module 6 Rechargeable Li Ion batteries BT11K 7 START push button 8 Hoist selection push button Use...

Page 7: ...on The LED will blink green until the transmitter is linked with the receiver RX I II RX I I II II Data sheet I II 1 I II When the receiver confirms the link the status LED will turn to a fixed green...

Page 8: ...OM External Battery model BT11K Battery life 8hr 100 duty cycle Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to 167 F Storage Temperature Range...

Page 9: ...ting 2 4GHz Color and frequency Pulse frequency Description Action Blue fast pulses Starting the system establishing communications with radio and EEPROM Wait Blue continuous Stand by mode Set up syst...

Page 10: ...ng temperature 0 C to 45 C Discharge temperature 20 C to 60 C Charging mode Fast 2 5 h and intelligent Weight 23 g BC70K Battery Charger Set up The battery charger has two charging compartments that c...

Page 11: ...batteries and battery charger follow these recommendations Do not recharge the battery until it is completely flat as shown with red LED slow pulse on the transmitter Always charge the batteries at te...

Page 12: ...BC70K Battery Charger Dimensions Dimensions mm 97 15 103 31 30 10 23 50 127 90 2 57 User Manual IKORE B Transmitter Charger and battery 12 Danfoss May 2021 BC292582855621en 000201...

Page 13: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...