1. Proceed to connect the power supply and the outputs
according to the connection block diagram provided with the
system. The configuration of the radio node can last up to 1
minute.

2. Place the EEPROM and the charged alkaline batteries.

3. If the transmitter has the STOP button, press and pull it out.
The status LED will blink in blue until the Stand-by mode is
reached, then it will turn into fixed blue.

4. If the transmitter does not have the STOP button, press the
start button. The status LED will blink in green until the
transmitter is linked with the receiver.

5. When the receiver confirms the link, the status LED will turn
into fixed green, and will enter working mode. The system will
be fully operational in order to action any maneuver.