Danfoss ICAD 600B Installation Manual Download Page 2

© Danfoss | Climate solutions | 2023.09 

2 | AN461947453648en-000101

ICAD 600B / ICAD 600B

/ ICAD 1200B

ICAD 600B/1200B - Analog I/O for modulating control

ICAD 600B/600B-TS/1200B - Digital I/O for ON/OFF valve operation

External
voltage

24 V DC

(+)
(–)

K

1

K

2

K

1

K

2

II III

Supply

D         F         G

E

DI1

DI2

Control

ICAD

Danf

oss

M27H0163_1

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)

G (Blue)

EKC 347
EKC 315A
EKC 361

Neutral zone/3 points control

Only possible with EKC 347

6

7

8

9

(Y
(G

)

Control 

Power supply cable

cable

Terminal box

2

1

3

2

1

3

  

Data cable

 

 

2

1

3

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)
G (Blue)

EKE 347

Only possible with EKE 347

Only possible with EKE 347

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)

G (Blue)

DC

Auxiliary relays

24 V DC

Power

Control

Data

2

1

3

(White/blue)
(White/orange)

(Orange)

(Blue)

A  (Black)

(Black)
(White)
(Brown)
(Blue)

B  (Brown)
C  (Red)
D  (Orange)
E  (Yellow)
F  (Green)
G  (Blue)

ICAD back

Ref

Color

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)

G (Blue)

EKC 347
EKC 315A
EKC 361

Only possible with EKC 347

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)
G (Blue)

EKE 347

Only possible with EKE 347

Only possible with EKE 347

A (Black)
B (Brown)
C (Red)
D (Orange)
E (Yellow)
F (Green)

G (Blue)

DC

Auxiliary relays

24 V DC

A

Black

-

Common alarm

B

Brown

-

ICM fully open

C

Red

-

ICM fully closed

D

Orange

-

GND ground

E

Yellow

+

0/4 – 20 mA Input

F

Green

+

0/2 – 10 V input or digital input for on/off control

G

Blue

+

0/4 – 20 mA Output

I

Black

+

Fail safe supply. Battery / UPS* 19 V DC

II

White

+

Supply voltage
24 V DC 2A, or more, per ICAD recommended
ICAD PSU must be SELV**, >15 W

III

Brown

-

IIII

Blue

+

UPS Signal of Health - optional depending on ID31:
‘UPS supply’ set to ‘Yes’

*Uninterruptable Power Supply

Digital
output

ICAD back

Ref

Color

  RS 485 / Ethernet               

1

White/Blue

2

White/Orange

3

Blue

4

Orange

(-) / TX+

Data – (B) / Transmit Pair(+) 

GND / RX+                    Ground / Receiving Pair(+) 
(+) / TX-                

Data + (A) / Transmit Pair(-) 

GND / RX-                                   

Ground / Receiving Pair(-) 

*Uninterruptable Power Supply
** The ICAD is a Class III appliance

  RS 485 / Ethernet              

  RS 485 / Ethernet              

  RS 485 / Ethernet               

Description

  RS 485 / Ethernet              

  RS 485 / Ethernet               